|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Microfluidizer Á¾ÇÕÄ«´Ù·Î±× |
Phone |
|
|
  ´ëÇ¥ÀüÈ |
1577-7956   |
  º»     »ç |
031-457-9187   |
  ´ë     Àü |
042-932-1265 |
|
|
Web Site Visitors |
|
|
  Today |
534     |
  Yesterday |
800     |
  Since 2006 |
1,918,131     |
|
|
|
|
¿µÁøÄÚÆÛ·¹ÀÌ¼Ç Á¾ÇÕÄ«´Ù·Î±× |
|
|
Industry : |
| |
Biopharmaceutical |
| | |
Product : |
| |
Yeast Cell |
| | |
Test Objective : |
| |
Obtain 90% cell disruption of yeast cells |
| | |
Processor : |
| |
M-110EH     (Microfluidizer High Shear Processor Àåºñº¸±â) |
| | |
Chambers : |
| |
- Interaction Chamber (downstream) H10Z
- Auxiliary processing Module (upstream) H30Z |
| | |
Number of passes : |
| |
5 |
| | |
Shear per pass : |
| |
5,780,000 sec -1 |
| | |
Process pressure : |
| |
25,000 psi |
| | |
Summary of results : |
| |
Achieved greater than 90% cell disruption after 5 passes using the M-110EH Microfluidizer materials processor
(pdf ÈÀÏ ´Ù¿î·Îµå) |
|
|
|
|
  |
|
|
|
|
|
|
|