Phone
  ´ëÇ¥ÀüÈ­ 1577-7956  
  º»     »ç 031-457-9187  
  ´ë     Àü 042-932-1265

Web Site Visitors
  Today 505    
  Yesterday 897    
  Since 2006 1,916,221    


¿µÁøÄÚÆÛ·¹ÀÌ¼Ç Á¾ÇÕÄ«´Ù·Î±×

iQue 3 Flow Cytometry Brochure ´Ù¿î·Îµå

Interactive Assay Development, Analysis, and Multiparameter Data Visualization
iQue Forecyt¢ç Software ´Â ÀüÅëÀûÀÎ flow cytometer software ¿¡¼­´Â º¼ ¼ö ¾ø´Â °¢ plate ¿¡ ´ëÇÑ ÁÖ¼®À» ´Þ°í, ¼öÁýµÈ µ¥ÀÌÅ͸¦ ºÐ¼®ÇÏ°í, ºÐ¼®µÈ °á°ú¸¦ ±×·¡ÇÁ, µµÇ¥ µî ´Ù¾çÇÑ ¹æ¹ýÀ¸·Î ½Ã°¢ÀûÀ¸·Î Ç¥ÇöÇÏ¿© ÁÝ´Ï´Ù.

¸ðµç well ¿¡¼­ÀÇ µ¥ÀÌÅ͸¦ ¿¬°áÇÏ°í °¢ ½ÇÇè°á°ú¿Í Á¾ÇÕÇÏ¿© »ç¿ëÀÚ°¡ Hits ¸¦ ½Å¼ÓÈ÷ È®ÀÎÇÏ°í ½ÇÇè°á°ú¿¡ ´ëÇÑ ±íÀº ÀÌÇظ¦ ÇÒ ¼ö ÀÖµµ·Ï µµ¿Í ÁÝ´Ï´Ù.

Ordering Information
Forecyt¢ç Standard Edition Forecyt¢ç Offline Edition Forecyt¢ç Enterprise Edition
Number of Computers One One Many
Number of Instruments One None Many
Number of Users Single Single Multiple
Distributed Client Access No No Yes



iQue Forecyt¢ç Software Features

One Stop Workflow
ÀÌÇØÇϱ⠽¬¿î 6´Ü°èÀÇ Assay ±¸Ãà ȯ°æÀ» Á¦°øÇϸç Àüü Plate ¿¡ ´ëÇÑ ºÎ°¡¼³¸í°ú ºÐ¼®À» ÀÔ·ÂÇÒ ¼ö ÀÖ½À´Ï´Ù. IC/EC50 curves ¿Í °°Àº Plate Level ÀÇ ºÐ¼®À» ¼³Á¤Çϸé standard curve °¡ ÀÚµ¿À¸·Î »ý¼ºÀÌ µË´Ï´Ù.

Interactive Gating with Real Time Results
Plate Àüü data ¿¡ ´ëÇØ gating À» Çѹø¿¡ ÁøÇàÇÏ¿© Assay ¸¦ ¼Õ½±°Ô ÃÖÀûÈ­ÇÒ ¼ö ÀÖ½À´Ï´Ù. Gate ¸¦ º¯°æÇÏ¸é ±×¿¡ µû¸¥ °á°ú°ªÀÌ ½Ç½Ã°£À¸·Î º¯ÇÏ°Ô µÇ¾î »ç¿ëÀÚ°¡ Gate º¯È­¿¡ µû¸¥ È¿°ú¸¦ Áï½Ã È®ÀÎÇÒ ¼ö ÀÖ°Ô ÇÕ´Ï´Ù.

Generate the Data You Need and Share It
°£´ÜÇÑ ¸¶¹ý»ç ±â´ÉÀ» ÀÌ¿ëÇÏ¿© ±âº»ÀûÀÎ metrics building blocks À¸·ÎºÎÅÍ »ç¿ëÀÚ Á¤ÀÇ metrics ¸¦ »ý¼ºÇÒ ¼ö ÀÖ½À´Ï´Ù.
¸ðµç metrics ´Â ´Ù½Ã Ãß°¡ÀûÀ¸·Î ºÐ¼®ÇÏ¿© ÀûÀýÇÏ°Ô visualization ÇÒ ¼ö ÀÖ½À´Ï´Ù.
¶ÇÇÑ ÀÌ metrics ¿¡ ´ëÇÑ report ¸¦ ¾ÆÁÖ Æí¸®ÇÏ°Ô ÀÛ¼ºÇÏ¿© ´Ù¸¥ µ¿·áµé°ú °øÀ¯ÇÒ ¼ö ÀÖ½À´Ï´Ù.

Data Visualizations Linked by Well
Well Scan À̶ó´Â Ź¿ùÇÑ ±â´ÉÀÌ ÀÖ¾î Àüü well ¿¡¼­ »ý¼ºµÈ ¸ðµç ±×·¡ÇÁµéÀ» º¸¿©ÁÙ ¼ö ÀÖ½À´Ï´Ù.
»ç¿ëÀÚ´Â °¢ well ¿¡¼­ »ý¼ºµÈ ±×·¡ÇÁ¸¦ ¾ÆÁÖ Æí¸®ÇÏ°í ½Å¼ÓÇÏ°Ô È®ÀÎÀ» ÇÒ ¼ö ÀÖ½À´Ï´Ù.

Make Decisions Easier with Profile Mapping
´Ù¾çÇÑ Á¤º¸¸¦ °¡Áø µ¥ÀÌÅ͸¦ ÀÌÇØÇÏ°í Á¤È®ÇÑ Æ¯Â¡À» °¡Áø sample À» ã´Â °Í¿¡´Â ¸¹Àº ½Ã°£ÀÌ °É¸³´Ï´Ù.
¿ì¸®´Â »ç¿ëÀÚÀÇ ´Ù¾çÇÑ Á¶°ÇÀ» ÃæÁ·½ÃÅ°´Â well ÀÌ ¾îµð¿¡ ÀÖ´ÂÁö ã´Â ÀÛ¾÷À» ½±°ÔÇÒ ¼ö ÀÖµµ·Ï ½ÇÇè °á°ú°ª°ú Boolean logic À» ¼­·Î ¿¬°è½ÃÅ°´Â ¹æ¹ýÀ» Á¦°øÇÕ´Ï´Ù.

Create a Plate Level View of All Well Graphs
ÇÑ ¹øÀÇ ¸¶¿ì½º Ŭ¸¯À¸·Î ¾î¶² ±×·¡ÇÁ³ª È÷½ºÅä±×·¥À» plate well data thumbnails ·Î ±¸¼ºµÈ Plate View ·Î º¯È¯ÇÏ¿© ½Ã°¢ÀûÀ¸·Î ºñ±³ÇÒ ¼ö ÀÖ½À´Ï´Ù

Analyze Multiple Plates Across Your Experiment
iQue Forecyt¢ç Software ÀÇ Panorama ±â´ÉÀ» ÀÌ¿ëÇÏ¿© Àüü ½ÇÇèÀ» ½º³À¼¦À¸·Î ÀúÀåÇÒ ¼ö ÀÖ½À´Ï´Ù.
Plate Àüü µ¥ÀÌÅ͸¦ È®ÀÎÇÑ ÈÄ Hit Map À» ºñ±³ÇÏ°í, profile map Àüü¿¡¼­ Á¶°Ç¿¡ ÀûÇÕÇÑ Hit ¸¦ È®ÀÎÇÏ°í¼­ °¢ plate well À» ¶óÀÎ ±×·¡ÇÁ ¹æ½ÄÀ¸·Î ¼øÀ§¸¦ ¸Å±æ ¼ö ÀÖ½À´Ï´Ù.


iQue Forecyt¢ç 9.1 -- See what is new!
°¡Àå °­·ÂÇÑ Cell and Cytokine analysis software ¸¦ »ç¿ëÇÒ ¼ö ÀÖ½À´Ï´Ù.
iQue¢ç Screener Plus ¿Í iQue¢ç 3 platforms ÀÇ ÀÌ »õ·Î¿î version À» ÀÌ¿ëÇÏ¸é »ç¿ëÀÚÀÇ µ¥ÀÌÅÍ ºÐ¼®ÀÌ ÇÑÃþ ·¹º§ ¾÷ µÇ¾îÁý´Ï´Ù.
´ÙÀ½°ú °°Àº °­·ÂÇÑ »õ·Î¿î Ãß°¡ ±â´ÉÀÌ ÀÖ½À´Ï´Ù.
Elliptical Gates : ±âÁ¸ÀÇ Polygon °ú Rectangular Gate ¿Ü¿¡ Elliptical Gate ¸¦ Ãß°¡ÇÏ¿´½À´Ï´Ù. ÀÌ Gate ´Â Smart Gate ·Îµµ »ç¿ëÇÏ¿© Plate Well ¿¡¼­ sample ÀÇ Á¤È®ÇÑ À§Ä¡¸¦ ¿¹ÃøÇÒ ¼ö ÀÖ½À´Ï´Ù.
Bar Graphs : ´Ù¸¥ ±×·¡ÇÈ ÇÁ·Î±×·¥ÀÇ µµ¿ò ¾øÀÌ iQue Forecyt¢ç 9.1 ¿¡¼­ Á÷Á¢ ¸·´ë ±×·¡ÇÁ¸¦ »ý¼ºÇÒ ¼ö ÀÖ½À´Ï´Ù.
Multiple Metric Overlays : ¶óÀÎ ±×·¡ÇÁ¸¦ »ç¿ëÇÏ¿© ¿©·¯ ÁöÇ¥¸¦ ÇϳªÀÇ Plot À§¿¡ °ãÃļ­ Ç¥ÇöÇÒ ¼ö ÀÖ½À´Ï´Ù ÀÌ ±â´ÉÀº µ¿ÀÏÇÑ Plot À§¿¡¼­ ¿©·¯ dose response curve ¸¦ °üÂûÇÒ ¶§ ¹ÏÀ» ¼ö ¾øÀ» Á¤µµ·Î È¿À²ÀûÀÔ´Ï´Ù. ¼±Çü±×·¡ÇÁ¿Í ¸·´ë±×·¡ÇÁ ¸ðµÎ ´Ù¾çÇÑ »ö»óÀ¸·Î »ç¿ëÀÚ°¡ º¯ÇüÇÒ ¼ö ÀÖ½À´Ï´Ù. ¶óº§°ú ¹ü·Êµµ Ç¥½ÃµÇ´Â ¼ø¼­¿Í °°Àº ´Ù¾çÇÑ ¹æ½ÄÀ¸·Î »ç¿ëÀÚ°¡ ¼³Á¤ÇÒ ¼ö ÀÖ½À´Ï´Ù.
Panorama Graphs : ¼±Çü±×·¡ÇÁ¿Í ¸·´ë±×·¡ÇÁ ¸ðµÎ Panorama À§¿¡ »ý¼º½ÃÄÑ ÀÌÀü ½ÇÇè¿¡¼­ ±¸ÇÑ °á°ú¿Í µ¿½Ã¿¡ Á÷Á¢ÀûÀ¸·Î ºñ±³°¡ °¡´ÉÇÕ´Ï´Ù.



 
(ÁÖ)¿µÁøÄÚÆÛ·¹ÀÌ¼Ç   |   ´ëÇ¥ : ÀÌÇü¿­   |   »ç¾÷ÀÚµî·Ï¹øÈ£ : 138-81-34745
±º Æ÷ º» »ç   |   (15853) °æ±âµµ ±ºÆ÷½Ã ÇѼ¼·Î 48 ³²¿øºôµù 2Ãþ   |   ÀüÈ­ : 1577-7956 (1)   |   Æѽº : 031-457-9188   |   À̸ÞÀÏ : info@yjcorp.co.kr
´ë Àü Áö »ç   |   (34036) ´ëÀü½Ã À¯¼º±¸ Å×Å©³ë10·Î 29 ÆÄÅ©ÆÓ¸®½º 2Ãþ   |   ÀüÈ­ : 1577-7956 (2)   |   Æѽº : 042-932-1266   |   À̸ÞÀÏ : info@yjcorp.co.kr