Phone
  ´ëÇ¥ÀüÈ­ 1577-7956  
  º»     »ç 031-457-9187  
  ´ë     Àü 042-932-1265

Web Site Visitors
  Today 218    
  Yesterday 1445    
  Since 2006 1,900,843    


¿µÁøÄÚÆÛ·¹ÀÌ¼Ç Á¾ÇÕÄ«´Ù·Î±×

Á¦   Á¶   »ç : Bettersize Instruments Inc. (China)
Á¦ Ç° Ư ¡ : 1995³â ¼³¸³µÈ Bettersize »ç´Â Particle Sizing ºÐ¾ß¿¡¼­ ¼¼°èÀûÀ¸·Î ÀÎÁ¤¹Þ´Â ±â¾÷À¸·Î¼­ ³ª³ë¹ÌÅÍ¿¡¼­ ¹Ð¸®¹ÌÅÍ¿¡ À̸£´Â ´Ù¾çÇÑ Å©±âÀÇ ÀÔÀÚ¸¦ Á¤¹Ð ºÐ¼®ÇÒ ¼ö ÀÖ´Â °íÇ°ÁúÀÇ Paticle Size Analyser ¸¦ °ø±ÞÇØ ¿ÔÀ¸¸ç Àü¼¼°è ¼ö¸¸°³ÀÇ Çб³, ±â°ü, ¿¬±¸¼Ò µî¿¡¼­ ³Î¸® »ç¿ëµÇ°í ÀÖ½À´Ï´Ù. Bettersize »ç´Â Particle Characterization ±× ÀÌ»óÀÇ ¼Ö·ç¼ÇÀ» ¿©·¯ºÐµé¿¡°Ô Á¦°øÇÏ°í ÀÖ½À´Ï´Ù.



BeNano series Particle Size Analyser
 
 
- Size Range : 0.3nm ~ 15¥ìm
- Minimum sample volume : 3¥ìL
- APD (Avalanche Photodiode) detector ÀåÂø : Ź¿ùÇÑ Á¤¹Ðµµ
- 90¡Æ °¢µµ¿¡¼­ Dynamic Light Scattering ÃøÁ¤
- DLS backscattering (173¡Æ) ÃøÁ¤¿¡ ÀÇÇÑ Ãʹ̼¼ ÀÔÀÚ ÃøÁ¤
- PALS (Phase Analysis Light Scattering) technology : Á¦Å¸Æ÷ÅÙ¼È ÃøÁ¤
- Compliance with 21 CFR Part 11, ISO 22412, ISO 13099



Bettersizer S3 Plus Particle Size & Shape Analyser
- ·¹ÀÌÀúȸÀý¿¡ ÀÇÇÑ ÀÔµµ ºÐ¼®½Ã½ºÅÛ°ú CCD camera ¸¦ ÀÌ¿ëÇÏ´Â Dynamic À̹ÌÁö ºÐ¼®½Ã½ºÅÛÀÌ ÇϳªÀÇ Àåºñ¿¡ ÅëÇÕ
- Size Range by Laser Diffraction : 0.01 - 3,500¥ìm
- Size Range by Dynamic Image System : 2 - 3,500¥ìm
- ±ØÃʹ̼¼ ÀÔÀÚ ÃøÁ¤ : ƯÇã¹ÞÀº DLOI (Dual Lenses & Oblique Incidence) system ¿¡ ÀÇÇØ ±ØÃʹ̼¼ ÀÔÀÚ ÃÊÁ¤¹Ð ÃøÁ¤
- ±¼ÀýÀ²À» ¸ð¸¦°æ¿ì ³»ÀåµÈ ÃøÁ¤½Ã½ºÅÛÀÌ Á¦°øÇÏ´Â RI °ª ÀÌ¿ë
- 0.02¡Æ - 165¡Æ ³ÐÀº °¢µµ¿¡¼­ 96°³ÀÇ °ËÃâ±â ÀÌ¿ë
- Comply with 21 CFR Part 11, ISO-22412, ISO-13099 µî


Bettersizer 2600 series Particle Size Analyser
 
- Àü¼¼°èÀûÀ¸·Î °¡Àå ¸¹ÀÌ ÆÇ¸ÅµÈ Bettersizer ÀÔµµºÐ¼®Àåºñ
- ·¹ÀÌÀúȸÀý¿¡ ÀÇÇÑ ½À½Ä ÀÔµµºÐ¼®°ú °Ç½Ä ÀÔµµºÐ¼®À» ¸ðµÎ ÇÒ ¼ö ÀÖ´Â ÀÔµµ ºÐ¼®Àåºñ
- Size Range by Wet Dispersion : 0.02 - 2,600¥ìm
- Size Range by Dry Dispersion : 0.1 - 2,600¥ìm
- Ãʹ̼¼ ÀÔÀÚ ÃøÁ¤ : Inversed Fourier ±¤ÇнýºÅÛ°ú ƯÇã¹ÞÀº Tilted sample cell À» »ç¿ëÇÏ¿© Ãʹ̼¼ Å©±â ÀÔÀÚ Á¤¹Ð ÃøÁ¤
- 0.016¡Æ - 165¡Æ ³ÐÀº °¢µµ¿¡¼­ 92°³ÀÇ °ËÃâ±â ÀÌ¿ë
- Comply with 21 CFR Part 11, ISO-13320, USP<429> µî


Bettersizer ST Particle Size Analyser
 
- »ê¾÷ »ý»êÇöÀå¿¡¼­ Ç°Áú°Ë»ç¿ëÀ¸·Î »ç¿ëµÇ´Â ÀÔµµºÐ¼®±â
- Laser Diffraction ÀÌ¿ë, wet type ÀÔµµºÐ¼® ÀÚµ¿ÃøÁ¤
- sample circulator °°Àº ºÎ¼ÓÀåÄ¡µé ¸ðµÎ ³»Àå
- ÀÔµµ ÃøÁ¤ ¹üÀ§ : 100 nm ~ 1,000 ¥ìm
- ƯÇã¹ÞÀº DLOS (Dual Lens Optical Systems) ÀåÂø
- 0.031 - 159¡Æ ÀÇ ³ÐÀº °¢µµ¿¡ ÃÑ 86°³ ±¤°ËÃâ±â ÀåÂø
- ¡¾1% ÀÇ Å¹¿ùÇÑ Á¤¹Ðµµ
- ¡Â1% variation ÀÇ Å¹¿ùÇÑ ÀçÇö¼º
- Compliance with 21 CFR Part 11, ISO 22412, ISO 13099



 
(ÁÖ)¿µÁøÄÚÆÛ·¹ÀÌ¼Ç   |   ´ëÇ¥ : ÀÌÇü¿­   |   »ç¾÷ÀÚµî·Ï¹øÈ£ : 138-81-34745
±º Æ÷ º» »ç   |   (15853) °æ±âµµ ±ºÆ÷½Ã ÇѼ¼·Î 48 ³²¿øºôµù 2Ãþ   |   ÀüÈ­ : 1577-7956 (1)   |   Æѽº : 031-457-9188   |   À̸ÞÀÏ : info@yjcorp.co.kr
´ë Àü Áö »ç   |   (34036) ´ëÀü½Ã À¯¼º±¸ Å×Å©³ë10·Î 29 ÆÄÅ©ÆÓ¸®½º 2Ãþ   |   ÀüÈ­ : 1577-7956 (2)   |   Æѽº : 042-932-1266   |   À̸ÞÀÏ : info@yjcorp.co.kr