Industry : |
| |
Nutraceutical |
| | |
Product : |
| |
Liposomal Vitamin C |
| | |
Test Objective : |
| |
Reduce mean particle size to 0.2 um. |
| | |
Processor : |
| |
M-110Y     (Microfluidizer High Shear Processor Àåºñº¸±â) |
| | |
Chambers : |
| |
- Interaction Chamber (upstream) F20Y (75 um)
- Auxiliary Processing Module (downstream) H30Z (200 um) |
| | |
Number of passes : |
| |
4 |
| | |
Shear per pass : |
| |
6,800,000 sec-1 |
| | |
Process pressure : |
| |
22,000 psi |
| | |
Median Particle size : |
| |
- Premix : 4.19 um
- 4 Pass : 0.195 um |
| | |
Summary of results : |
| |
After 4 passes, the particle size was reduced to 0.195 um. &
(pdf ÈÀÏ ´Ù¿î·Îµå) |
| | |
|
|
|