Product : Liposomal Vitamin C
Test Objective : Reduce mean particle size to 0.2 um.
Processor : M-110Y     (Microfluidizer High Shear Processor Àåºñº¸±â)
Chambers : - Interaction Chamber (upstream) F20Y (75 um)
- Auxiliary Processing Module (downstream) H30Z (200 um)
Number of passes : 4
Shear per pass : 6,800,000 sec-1
Process pressure : 22,000 psi
Median Particle size : - Premix : 4.19 um
- 4 Pass : 0.195 um
Summary of results : After 4 passes, the particle size was reduced to 0.195 um. &