Microfluidizer Á¾ÇÕÄ«´Ù·Î±×


Phone
  ´ëÇ¥ÀüÈ­ 1577-7956  
  º»     »ç 031-457-9187  
  ´ë     Àü 042-932-1265

Web Site Visitors
  Today 656    
  Yesterday 508    
  Since 2006 1,945,779    


¿µÁøÄÚÆÛ·¹ÀÌ¼Ç Á¾ÇÕÄ«´Ù·Î±×
 
¸®½ºÆ®µ¹¾Æ°¡±â

Industry : Cosmetics
Product : Liposome and vitamin E mixture
Test Objective : Deposit vitamin E into liposomes and reduce individual liposome droplet size
Processor : M-110EH-30     (Microfluidizer High Shear Processor Àåºñº¸±â)
Number of passes : 2
Process pressure : 12,000 psi
Median Particle size : - Premix : 5,281 nm
- 3 Passes : 72 nm
Summary of results : The liposome was produced successully using the Microfluidizer processor. The average particle size of the liposome was reduced from 5,2181 nm to 72 nm after 2 passes    