Industry : Pharmaceutical
Product : 5% Phthalocyanine blue pigment dispersion
Test Objective : Reduce 99% of particles to below 0.5um
Processor : M-110Y with cooling chamber     (Microfluidizer High Shear Processor Àåºñº¸±â)
Chambers : - Interaction Chamber (downstream) H30Z (200um)
- Auxiliary Processing Module (upstream) G10Z (87um)
Number of passes : Continuous processing for 40 passes
Shear per pass : 5,600,000 sec -1
Process pressure : 21,000 psi
Particle Size : - Premix : 4.109 um mean particle size (D99 = 15.733um)
- 40 Passes : 0.142 um mean particle size [D99 = 0.43 um)
Summary of results : Reduced 99% of particles to 0.43 um in 40 passes of continuous processing on an M-110Y Microfluidizer materials processor.