Microfluidizer Á¾ÇÕÄ«´Ù·Î±× |
Phone |
|
|
  ´ëÇ¥ÀüÈ |
1577-7956   |
  º»     »ç |
031-457-9187   |
  ´ë     Àü |
042-932-1265 |
|
|
Web Site Visitors |
|
|
  Today |
1039     |
  Yesterday |
897     |
  Since 2006 |
1,916,755     |
|
|
|
|
¿µÁøÄÚÆÛ·¹ÀÌ¼Ç Á¾ÇÕÄ«´Ù·Î±× |
|
|
Industry : |
| |
Pharmaceutical |
| | |
Product : |
| |
Penicillin suspension |
| | |
Test Objective : |
| |
Reduce mean particle size to 10 - 15 um |
| | |
Processor : |
| |
M-210B     (Microfluidizer High Shear Processor Àåºñº¸±â) |
| | |
Chambers : |
| |
Auxiliary Processing Module (upstream) H230Z (400 um)
Interaction Chamber (downstream) J210Z (250 um) |
| | |
Number of passes : |
| |
1 |
| | |
Shear per pass : |
| |
2,312,200 sec -1 |
| | |
Process pressure : |
| |
18,000 psi |
| | |
Mean particle size : |
| |
Premix : 53 um 1 process pass : 12.1 um |
| | |
Summary of results : |
| |
After 1 pass, the particle size was reduced to 12 um    