Microfluidizer Á¾ÇÕÄ«´Ù·Î±×


Phone
  ´ëÇ¥ÀüÈ­ 1577-7956  
  º»     »ç 031-457-9187  
  ´ë     Àü 042-932-1265

Web Site Visitors
  Today 532    
  Yesterday 800    
  Since 2006 1,918,129    


¿µÁøÄÚÆÛ·¹ÀÌ¼Ç Á¾ÇÕÄ«´Ù·Î±×
 
¸®½ºÆ®µ¹¾Æ°¡±â

Industry : Pharmaceutical
Product : 60% Bisphenol epoxy resin / water dispersion
Test Objective : Reduce the mean particle size from 1.5 ~ 1.7 um to 0.5 ~ 0.8 um
Processor : M-110Y     (Microfluidizer High Shear Processor Àåºñº¸±â)
Chambers : - Interaction Chamber (downstream) G10Z (87um)
- Auxiliary Processing Module (upstream) H30Z (200um)
Number of passes : 15
Shear per pass : 3,900,000 sec-1
Process pressure : 10,000 psi
Particle size : - Premix : 1.486 um um
- 15 Passes : 0.733um
Summary of results : The Microfluidizer materials processor reduced the particle size to 0.733 in 15 passes at 10,000 psi.
(pdf È­ÀÏ ´Ù¿î·Îµå)











 
(ÁÖ)¿µÁøÄÚÆÛ·¹ÀÌ¼Ç   |   ´ëÇ¥ : ÀÌÇü¿­   |   »ç¾÷ÀÚµî·Ï¹øÈ£ : 138-81-34745
±º Æ÷ º» »ç   |   (15853) °æ±âµµ ±ºÆ÷½Ã ÇѼ¼·Î 48 ³²¿øºôµù 2Ãþ   |   ÀüÈ­ : 1577-7956 (1)   |   Æѽº : 031-457-9188   |   À̸ÞÀÏ : info@yjcorp.co.kr
´ë Àü Áö »ç   |   (34036) ´ëÀü½Ã À¯¼º±¸ Å×Å©³ë10·Î 29 ÆÄÅ©ÆÓ¸®½º 2Ãþ   |   ÀüÈ­ : 1577-7956 (2)   |   Æѽº : 042-932-1266   |   À̸ÞÀÏ : info@yjcorp.co.kr