Industry : Pharmaceutical
Product : 60% Bisphenol epoxy resin / water dispersion
Test Objective : Reduce the mean particle size from 1.5 ~ 1.7 um to 0.5 ~ 0.8 um
Processor : M-110Y     (Microfluidizer High Shear Processor Àåºñº¸±â)
Chambers : - Interaction Chamber (downstream) G10Z (87um)
- Auxiliary Processing Module (upstream) H30Z (200um)
Number of passes : 15
Shear per pass : 3,900,000 sec-1
Process pressure : 10,000 psi
Particle size : - Premix : 1.486 um um
- 15 Passes : 0.733um
Summary of results : The Microfluidizer materials processor reduced the particle size to 0.733 in 15 passes at 10,000 psi.