Microfluidizer Á¾ÇÕÄ«´Ù·Î±×


Phone
  ´ëÇ¥ÀüÈ­ 1577-7956  
  º»     »ç 031-457-9187  
  ´ë     Àü 042-932-1265

Web Site Visitors
  Today 504    
  Yesterday 747    
  Since 2006 1,942,344    


¿µÁøÄÚÆÛ·¹ÀÌ¼Ç Á¾ÇÕÄ«´Ù·Î±×
 
¸®½ºÆ®µ¹¾Æ°¡±â

Industry : Cosmetic
Product : Cosmetic Emulsion
Test Objective : Reduce particle size to < 150nm
Chambers : - Interaction Chamber (upstream) J30Y (125 um)
- Auxiliary Processing Module (downstream) Q50Z (425 um)
Processor : M-210EH-B     (Microfluidizer High Shear Processor Àåºñº¸±â)
Number of passes : 1
Shear per pass : 4,636,900 sec-1
Process pressure : 15,000 psi (1,000 bar)
Particle size : - Premix : 1,000 nm (mean diameter)
- 1 Pass : 130 nm (mean diameter)
Summary of results : Mean particle size of 150 nm was achieved in one pass at 15,000 psi (1,000 bar) using an M-210EH-B Microfluidizer materials processor
(pdf È­ÀÏ ´Ù¿î·Îµå)












 
(ÁÖ)¿µÁøÄÚÆÛ·¹ÀÌ¼Ç   |   ´ëÇ¥ : ÀÌÇü¿­   |   »ç¾÷ÀÚµî·Ï¹øÈ£ : 138-81-34745
±º Æ÷ º» »ç   |   (15853) °æ±âµµ ±ºÆ÷½Ã ÇѼ¼·Î 48 ³²¿øºôµù 2Ãþ   |   ÀüÈ­ : 1577-7956 (1)   |   Æѽº : 031-457-9188   |   À̸ÞÀÏ : info@yjcorp.co.kr
´ë Àü Áö »ç   |   (34036) ´ëÀü½Ã À¯¼º±¸ Å×Å©³ë10·Î 29 ÆÄÅ©ÆÓ¸®½º 2Ãþ   |   ÀüÈ­ : 1577-7956 (2)   |   Æѽº : 042-932-1266   |   À̸ÞÀÏ : info@yjcorp.co.kr