Industry : |
| |
Food |
| | |
Product : |
| |
Oil and water emulsion |
| | |
Test Objective : |
| |
Reduce particle size to 0.5 um |
| | |
Chambers : |
| |
- Interaction Chamber (upstream) H230Z (400 um)
- Auxiliary Processing Module (downstream) H210Z (200 um) |
| | |
Processor : |
| |
M-110Y     (Microfluidizer High Shear Processor Àåºñº¸±â) |
| | |
Number of passes : |
| |
1 |
| | |
Shear per pass : |
| |
830,000 sec-1 |
| | |
Process pressure : |
| |
3,000 psi |
| | |
Particle size : |
| |
- Premix : 5.97 um mean particle size [D90 = 12.5 um]
- 1 Pass : 0.61 um mean particle size [D90 = 0.98 um] |
| | |
Summary of results : |
| |
Customer's previous homogenization method reduced the droplet size to 5.0 um. The M-110Y Microfluidizer processor
reduced the mean droplet size to 0.607 um after 1 pass at 3,000 psi