Industry : Pharmaceutical
Product : 25% drug slurry to be delivered orally
Test Objective : Reduce the mean particle size to below 1 um
Processor : M-110Y     (Microfluidizer High Shear Processor Àåºñº¸±â)
Number of passes : 10
Process pressure : 18,000 psi
Particle size : - Premix : 28.407 um
- 10 Passes : 0.831 um
Summary of results : The mean particle size was reduced to below 1 um in 10 passes at 18,000 psi.