Phone
  ´ëÇ¥ÀüÈ­ 1577-7956  
  º»     »ç 031-457-9187  
  ´ë     Àü 042-932-1265

Web Site Visitors
  Today 503    
  Yesterday 897    
  Since 2006 1,916,219    


¿µÁøÄÚÆÛ·¹ÀÌ¼Ç Á¾ÇÕÄ«´Ù·Î±×



Accelerate your research with an upgradable, label-free protein analysis platform
Octet¢ç R2 protein analysis platform
Octet¢ç R4 protein analysis platform
Octet¢ç R8 protein analysis platform
A Dip and Read biosensor, illustrating the two optical interfaces at the biosensor tip : the internal reference layer (optical layer) and the surface biocompatible matrix on which ligand molecules are immobilized
Cat. No.
Octet¢ç R2 System °ßÀû¿äû
Octet¢ç R4 System °ßÀû¿äû
Octet¢ç R8 System °ßÀû¿äû
Octet¢ç R Series ºê·Î½´
Octet¢ç R4 Datasheet


Octet¢ç Àº protein-protein ¶Ç´Â protein-drug ÀÇ »óÈ£¹ÝÀÀ°ú °°Àº molecular interaction À» screening ÇÏ°í characterization ÇÏ´Â Á¾ÇÕÀûÀÎ Ç÷§ÆûÀÔ´Ï´Ù.
Octet¢ç Biomolecular Interaction Analysis System Àº »ýüºÐÀÚ ¹ÝÀÀÀ» Çü±¤ labeling ¾øÀÌ ½Ç½Ã°£À¸·Î ºÐ¼®ÇÒ ¼ö ÀÖ´Â ½Ã½ºÅÛÀ¸·Î¼­ BLI (Bio-Layer Interferometry) ±â¼úÀ» »ç¿ëÇÏ°í ÀÖ½À´Ï´Ù.
(¿ø¸®»ó¼¼º¸±â)
¹ÙÀÌ¿ÀÀǾàÇ° °³¹ß°úÁ¤¿¡¼­ Ãʱâ´Ü°èºÎÅÍ ÃÖÁ¾ »ý»ê´Ü°è¿¡ À̸£±â±îÁö ÁøÇàµÇ´Â ¸Å¿ì ´Ù¾çÇÑ applications ¿¡¼­ »ç¿ëµË´Ï´Ù.
1. Competition | inhibitor assays
2. DNA | RNA binding proteins
3. Viruses | vaccines
4. Ligand binding
5. Glycans
6. ELISA replacement
7. Manufacturing control bioprocessing QC
8. Small molecules
9. Off-rate ranking
10. FC receptors
11. Aptamers
12. Biosimilars
3°¡Áö Á¾·ùÀÇ Octet¢ç R system
- Octet¢ç R2 system : 2°³ÀÇ channel À» ÀÌ¿ëÇÏ¿© ÃøÁ¤
- Octet¢ç R4 system : 4°³ÀÇ channel À» ÀÌ¿ëÇÏ¿© ÃøÁ¤
- Octet¢ç R8 system : 8°³ÀÇ channel À» ÀÌ¿ëÇÏ¿© ÃøÁ¤
=> ¾Æ·¡ À̹ÌÁö¸¦ ÂüÁ¶Çϼ¼¿ä
Octet¢ç R4 system Àº Octet¢ç R2 system º¸´Ù ¾à 2¹è ºü¸£°Ô »ùÇÃÀ» ÃøÁ¤ÇÕ´Ï´Ù.
Octet¢ç R8 system Àº Octet¢ç R4 system º¸´Ù ¾à 2¹è ºü¸£°Ô »ùÇÃÀ» ÃøÁ¤ÇÕ´Ï´Ù.
Octet¢ç R2 system Àº Octet¢ç R4 system À¸·Î °£´ÜÇÏ°Ô upgrade °¡´ÉÇÕ´Ï´Ù.
Octet¢ç R4 system Àº Octet¢ç R8 system À¸·Î °£´ÜÇÏ°Ô upgrade °¡´ÉÇÕ´Ï´Ù.
Çü±¤ labeling ¾øÀÌ »ýüºÐÀÚ ¹ÝÀÀÀ» ÃøÁ¤ÇÒ ¼ö ÀÖ½À´Ï´Ù.
½Ç½Ã°£À¸·Î »ýüºÐÀÚ binding interaction À» ÃøÁ¤ÇÒ ¼ö ÀÖ½À´Ï´Ù.
96 °³ÀÇ sample À» 5ºÐÀ̳»·Î ºÐ¼®ÇÒ ¼ö ÀÖ½À´Ï´Ù.
Àåºñ¸¦ ÀÌ¿ëÇÑ ÃøÁ¤ÀÌ ¸Å¿ì Æí¸®ÇÕ´Ï´Ù.
½Ã·áÀÇ Àüó¸® °úÁ¤¾øÀÌ ½Ã·á¸¦ ¹Ù·Î ÃøÁ¤ÀÌ °¡´ÉÇÕ´Ï´Ù.
150 Da Å©±âÀÇ ºÐÀÚ±îÁö detection ÇÒ ¼ö ÀÖÀ» Á¤µµ·Î ¸Å¿ì Á¤¹ÐÇÕ´Ï´Ù.
10pM ±îÁö ¸Å¿ì ¹Ì¼¼ÇÑ Affinity (KD) µµ ÃøÁ¤ °¡´ÉÇÕ´Ï´Ù.
Octet¢ç R8 system Àº ´ÙÀ½°ú °°Àº º¹ÀâÇÑ Á¶°ÇÀ» ¸ðµÎ Áö¿ø
- cGMP
- GLP (Good Laboratory Practice)
- GDP (Good documentation practice)
- GCP (Good Clinical Practice)
Octet¢ç R8 system Àº 21 CFR Part 11 Á¶°Çµµ Áö¿ø


Octet¢ç R Systems Àº R2, R4, R8 ¸ðµ¨ÀÌ ÀÖÀ¸¸ç ÀÚÀ¯·ÎÀÌ upgrade °¡ °¡´ÉÇÕ´Ï´Ù.
Octet¢ç R2 with 2 biosensor tips Octet¢ç R4 with 4 biosensor tips Octet¢ç R8 with 8 biosensor tips
Relative time taken for each assay on the Octet¢ç R systems : R8 < R4 < R2



Octet¢ç Àåºñ¸¦ ÀÌ¿ëÇÏ¿© ´ÙÀ½°ú °°Àº ¸Å¿ì ´Ù¾çÇÑ ½ÇÇèÀ» ÇÒ ¼ö ÀÖ½À´Ï´Ù.



Octet¢ç R Series Assay Capability
Applications R-Series Benefit
Quantitation assays (ELISA replacement) ¸Å¿ì Á¤¹ÐÇÑ °á°ú¸¦ ½Ç½Ã°£À¸·Î ±¸ÇÒ ¼ö ÀÖ½À´Ï´Ù.
Screening Application
(epitope binning, off-rate ranking)
mAbs ¸¦ ½Å¼ÓÇÏ°Ô ½ºÅ©¸®´×ÇÏ¿©, ÃÖÀûÀÇ Èĺ¸ ¼±Á¤À» À§ÇÑ ¿©·¯ °¡Áö Áß¿äÇÑ ¼Ó¼ºÀ» ±¸ÇÒ ¼ö ÀÖ½À´Ï´Ù.
Large molecule applications
(e.g., viruses, VLPs, nanoparticles)
ÇϳªÀÇ Àåºñ¸¦ ÀÌ¿ëÇÏ¿© ¸Å¿ì ´Ù¾çÇÑ Á¾·ùÀÇ ºÐÀÚµéÀ» ¿¬±¸ÇÒ ¼ö ÀÖ¾î ÅõÀÚ °¡Ä¡¸¦ ±Ø´ëÈ­ ÇÒ ¼ö ÀÖ½À´Ï´Ù.
Antibody characterization, DNA, RNA, Peptides, Protein analytes ¸Å¿ì ´Ù¾çÇÑ Á¾·ùÀÇ »ý¹°ÀǾàÇ°ÀÇ Æ¯¼ºÀ» ¼Õ½±°Ô ºÐ¼®ÇÒ ¼ö ÀÖ½À´Ï´Ù.
Measuring Weak Binding Affinities ELISA ¿¡¼­´Â ³õÄ¡±â ½¬¿î ¸Å¿ì ³·Àº affinity ¸¦ °¡Áø binder µµ È®ÀÎÀÌ °¡´ÉÇÕ´Ï´Ù.
Measuring Tight Binding Affinities PM affinity ¿¡ À̸£´Â ¸Å¿ì ³·Àº °áÇÕ·ÂÀ» °¡Áø binder µµ ÃøÁ¤ÇÒ ¼ö ÀÖ½À´Ï´Ù.
Small Molecule Applications 150 Da ÀÇ ¸Å¿ì ÀÛÀº ºÐÀÚ±îÁö ÃøÁ¤ÇÒ ¼ö ÀÖ½À´Ï´Ù.
Target ID/Lead Optimization ºÐ¼® 󸮷®À» ¼Õ½±°Ô ´Ã¸± ¼ö ÀÖ¾î ÃʱâÀÇ Å½»ö °³¹ß´Ü°è¸¦ È¿À²ÀûÀ¸·Î ÁøÇàÇÒ ¼ö ÀÖ½À´Ï´Ù.
Pre-clinical Development ¹é½Å°ú °°Àº ÀÛ¾÷À» ÁøÇàÇÑ ÈÄ Ç×üÀÇ ¹ÝÀÀÀ» Á¤È®È÷ ÃøÁ¤ÇÒ ¼ö ÀÖ½À´Ï´Ù.
Process Development / Monitoring ƯÁ¤ °øÁ¤À̳ª »ý»ê °úÁ¤¿¡¼­ Áß¿äÇÑ Ç°Áú ¼Ó¼ºÀ» ½Äº°ÇÏ°í, À̸¦ Á¤È®ÇÏ°Ô ÃøÁ¤ÇÒ ¼ö ÀÖ½À´Ï´Ù.
Quality Control ·ÎÆ® Ãâ½Ã ¹× °øÁ¤ Å×½ºÆ®¸¦ È®½ÅÀ» °¡Áö°í ¼öÇàÇÒ ¼ö ÀÖ½À´Ï´Ù.



Octet¢ç R Series Technical Specifications
Common Technical Specifications for All Octet¢ç R Systems
Microplate Compatibility 96-well plate
Sample Volume 180 - 220 ¥ìL/well, non-destructive testing
Molecular Weight Detection >150 Da
On-rate (ka) Range (M-1 s-1) 101 - 107
Off-rate (ka) Range (s-1) 10-6 - 10-1
Affinity (KD) Range 1 mM - 10 pM
Temperature Control 15 - 40¡ÆC in 1¡ÆC increments
Data Collection Rate 2, 5 or 10 Hz
Orbital Flow Capacity Static or 100 - 1500 rpm
Specific Technical Specifications for Each Octet¢ç R System
Octet¢ç R2 Octet¢ç R4 Octet¢ç R8
Number of Spectrometers 2 4 8
Maximum Simultaneous Reads 2 4 8
Evaporation Cover No No Yes
GxP Compatibility No No Yes
Upgradeability To 4 and 8 channels To 8 channels No



Ordering Information and Related Products
Part Number UOM Description
Octet¢ç R2 / 30-0512 System Includes Octet¢ç R2 instrument, desktop computer, LCD monitor, accessory kit and one-year warranty
41-0327 Kit Octet¢ç R2 installation and Operational Qualification Kit
Octet¢ç R4 / 30-0514 System Includes Octet¢ç R4 instrument, desktop computer, LCD monitor, accessory kit and one-year warranty
41-0326 Kit Octet¢ç R4 installation and Operational Qualification Kit
Octet¢ç R8 / 30-0518 System Includes Octet¢ç R8 instrument, desktop computer, LCD monitor, accessory kit and one-year warranty
Octet¢ç R8-GxP Package /
30-0518-GxP
System Includes Octet¢ç R8 instrument, 21 CFR Part II software, desktop computer, LCD monitor, accessory kit, IQ/OQ/PQ kits and services, and one-year warranty
41-0325 Kit Octet¢ç R8 installation and Operational Qualification Kit
18-5132 Pack Single-use evaporation covers to extend the experiment up to 12 hours. Three covers per pack
18-1176 Kit Octet¢ç R8 Performance Qualification - Quantitation Ki
18-1177 Kit Octet¢ç R8 Performance Qualification - Kinetics Kit
18-1178 Kits Bundle Octet¢ç R8 Performance Qualification Kits Bundle
50-0296 Pack Software Validation Packag






 
(ÁÖ)¿µÁøÄÚÆÛ·¹ÀÌ¼Ç   |   ´ëÇ¥ : ÀÌÇü¿­   |   »ç¾÷ÀÚµî·Ï¹øÈ£ : 138-81-34745
±º Æ÷ º» »ç   |   (15853) °æ±âµµ ±ºÆ÷½Ã ÇѼ¼·Î 48 ³²¿øºôµù 2Ãþ   |   ÀüÈ­ : 1577-7956 (1)   |   Æѽº : 031-457-9188   |   À̸ÞÀÏ : info@yjcorp.co.kr
´ë Àü Áö »ç   |   (34036) ´ëÀü½Ã À¯¼º±¸ Å×Å©³ë10·Î 29 ÆÄÅ©ÆÓ¸®½º 2Ãþ   |   ÀüÈ­ : 1577-7956 (2)   |   Æѽº : 042-932-1266   |   À̸ÞÀÏ : info@yjcorp.co.kr