Phone
  ´ëÇ¥ÀüÈ­ 1577-7956  
  º»     »ç 031-457-9187  
  ´ë     Àü 042-932-1265

Web Site Visitors
  Today 137    
  Yesterday 747    
  Since 2006 1,941,977    


¿µÁøÄÚÆÛ·¹ÀÌ¼Ç Á¾ÇÕÄ«´Ù·Î±×



SER 158/6 Automatic Solvent Extractor
SER 158/3 Automatic Solvent Extractor
Cat. No.
S303A0380, SER 158/6 Automatic Solvent Extractor °ßÀû¿äû
S303A0390, SER 158/3 Automatic Solvent Extractor °ßÀû¿äû

Randall ÃßÃâ¹ýÀ» ±â¹ÝÀ¸·Î ºü¸£°í, Á¤¹ÐÇÏ°í, Á¤È®ÇÑ Áö¹æ ÇÔ·® ºÐ¼®À» °¡´ÉÇÏ°Ô ÇÏ´Â fully automatic solvent extractor
- SER 158/6 : 6 position
- SER 158/3 : 3 position


ÃßÃâ¿¡ ¼Ò¿äµÇ´Â ½Ã°£ÀÌ Soxhlet ÃßÃâ¹ýº¸´Ù 5¹è ºü¸¥ Randall ÃßÃâ¹ýÀ» ÀÌ¿ë
´ëºÎºÐ sample ÀÇ Áö¹æ ÇÔ·® ºÐ¼®À» À§ÇÑ solvent extraction ÀÌ °¡´É
Áö¹æ ÃßÃâ °úÁ¤ÀÌ ÀüÀÚµ¿À¸·Î ÀÌ·ç¾î Áü
ÇϳªÀÇ ControlPad ¸¦ ÀÌ¿ëÇÏ¿© 4´ëÀÇ SER 158/6 À» Á¶ÀýÇÒ ¼ö ÀÖ¾î Çѹø¿¡ ÃÑ 24°³ÀÇ sample À» µ¿½Ã¿¡ solvent extraction ÀÌ °¡´É
SER 158/3 ÀÇ °æ¿ì ÃÑ 12°³ÀÇ sample À» µ¿½Ã¿¡ ÃßÃâ ½ÇÇè °¡´É
´ëºÎºÐÀÇ À¯±â¿ë¸Å¸¦ »ç¿ë °¡´É
ÀüÅëÀûÀÎ Soxhlet ÃßÃâ¹ýº¸´Ù 5¹è ºü¸¥ ÃßÃ⠽ð£
Titanium Condenser ÀåÂø (ƯÇãÃâ¿ø)
¿©·¯°³ÀÇ ¼¾¼­¿¡ ÀÇÇØ ÃßÃâ °øÁ¤ÀÌ Á¤¹ÐÇÏ°Ô ÀÌ·ç¾î Áü
GLP (Good Laboratory Practice) ±ÔÁ¤¿¡ ºÎÇյǴ Àåºñ
GLP (Good Laboratory Practice) ÀÎÁõ Á¦Ç°
SolventXpress¢â : À¯±â¿ë¸Å¸¦ Àåºñ¾È¿¡ ÅõÀÔÇÒ ¶§ »ç¿ëÇÏ´Â dispensing system À¸·Î¼­ sealing ÀÌ ¿Ïº®ÇÏ°Ô ÀÌ·ç¾î Á® ÀÖ¾î À¯±â¿ë¸Å°¡ »õ´Â °ÍÀ» ¹æÁö
SafeEnd¢â : °ú¿­À» ¹æÁöÇϱâ À§ÇÑ ÀåÄ¡
»ç¿ëÀÚ°¡ Load & Go ¹öÆ°¸¸ Ŭ¸¯Çϸé Àüü ÃßÃâ °øÁ¤ÀÌ ÀüÀÚµ¿À¸·Î ÀÌ·ç¾î Áø´Ù.
ControlPad ÀÇ ÇÁ·Î±×·¥ ¼¼ÆÃÀÌ ¸Å¿ì ½±´Ù.
Controller ´Â Àú¿ï°ú ¿¬°á °¡´É
Supplied with
- A00000298, Grey butyl seal (3pcs/box)
- A00000297, Green viton seal (3pcs/box)
- A00000290, Extraction cup ¨ª 56x120mm (3pcs/box)
- A00000312, Extraction thimbles holder ¨ª 33mm
- A00000305, Boiling stones, 80g
- A00000295, Cellulose thimbles 33x80mm (25pcs/box)
- 10000280, Inlet water tube
- 10002866, Teflon tube ¨ª 4x6mm
- 10006054, Connection 1/8 NPT - tube 6x4


 



Fully Automatic Extraction Process
 
1. Immresion Step : sample ÀÌ ²ú°í ÀÖ´Â hot solvent ¼Ó¿¡¼­ ÃßÃâÀÌ ÀϾ°í ÀÖ´Â ´Ü°è
2. Removing Step : solvent ÀϺΰ¡ recovery tank ·Î À̵¿ÇÏ¿© thimble ¾Æ·¡ ³ôÀÌ·Î ÀÚµ¿À¸·Î ÁÙ¾îµé°í ÃßÃâÀº °è¼ÓµÇ´Â ´Ü°è
3. Washing Step : condenser ¿¡ ÀÇÇØ ³Ã°¢µÈ cold solvent ¿¡ ÀÇÇØ ¹°ÁúÀÌ washing µÇ¸é¼­ ÃßÃâÀÌ ¸¶¹«¸® µÇ´Â ´Ü°è
4. Recovery Step : valve ¸¦ ¿­¾î condenser ·Î ³»·Á¿À´Â cold solvent ¸¦ recovery tank ·Î ȸ¼öÇÏ´Â ´Ü°è
5. Cooling Step : È÷ÅÍ Àü¿øÀ» ²ô°í ÃßÃâ¹°ÀÌ µé¾îÀÖ´Â glass cup À» ÀÚµ¿À¸·Î »ó½Â½ÃÅ°´Â ´Ü°è






Specifications
SER 158/3 SER 158/6
Positions: 3-positions 6-positions
Max. Capacity: 21 samples/day/unit 42 samples/day/unit
Scalability: 12-pos. (up to 4 units) 24-pos. (up to 4 units)
Display: 7 inch color touch screen - extractable ControlPad
Solvents Accepted: Capable of being used with the majority of solvents
Solvent Recovery: > 90%
Automation: Immersion, Removing, Washing, Recovery, Cooling
Lighting: LED show 3/6 active positions
Heating Element: Glass ceramic - 3/6 positions independent switch on/off
Sample Size: 0.5 to 15 g in 33x80 mm thimbles (generally 2-3 g)
Seals: Viton, Butyl, and Vaflon
Condensers: Titanium (VELP Patent Pending)
Interfaces: 3 x USB (balance, mouse, USB stick), Ethernet (Pc)
Result Calculation: Automatic, archived on the ControlPad
Water Consumption: From 1.0 l/min
Dimensions (WxHxD): 358 x 546 x 450 mm 546 x 546 x 450 mm
Dimensions with ControlPad 358 x 546 x 570 mm 546 x 546 x 570 mm
Weight (SER 158/ControlPad): 29 kg 36 kg
Power Supply: 115/230 - 50/60 V-Hz 115/230 - 50/60 V-Hz
Power Consumption 630/850 W 630/850 W



 
(ÁÖ)¿µÁøÄÚÆÛ·¹ÀÌ¼Ç   |   ´ëÇ¥ : ÀÌÇü¿­   |   »ç¾÷ÀÚµî·Ï¹øÈ£ : 138-81-34745
±º Æ÷ º» »ç   |   (15853) °æ±âµµ ±ºÆ÷½Ã ÇѼ¼·Î 48 ³²¿øºôµù 2Ãþ   |   ÀüÈ­ : 1577-7956 (1)   |   Æѽº : 031-457-9188   |   À̸ÞÀÏ : info@yjcorp.co.kr
´ë Àü Áö »ç   |   (34036) ´ëÀü½Ã À¯¼º±¸ Å×Å©³ë10·Î 29 ÆÄÅ©ÆÓ¸®½º 2Ãþ   |   ÀüÈ­ : 1577-7956 (2)   |   Æѽº : 042-932-1266   |   À̸ÞÀÏ : info@yjcorp.co.kr