BMP and Other Anaerobic Respiration Tests |
 | |
| |
RESPIROMETRIC Sensor System 6 - BMP | |
| |
 | |
| |
RESPIROMETRIC Sensor | |
| |
 | |
| |
DataBox¢â and RESPIROSOFT¢â Software | |
| |
 | |
|
|
Cat. No. |
|
SA10200156, RESPIROMETRIC Sensor System Maxi 6 - BMP |
°ßÀû¿äû |
|
RESPIROMETRIC Sensor
RESPIROMETRIC Sensor ´Â Biochemical Oxygen Demand (BOD), Biochemical Methane Potential (BMP), Soil Respiration Test,
Plastic Biodegradibility Test µî°ú °°ÀÌ Respiration ¶Ç´Â Degradation ÀÇ ÃøÁ¤¿¡ »ç¿ëµÇ´Â Sensor ÀÌ´Ù
30ºÐ¿¡¼ 48½Ã°£À¸·Î ¼³Á¤µÈ ÃøÁ¤ ½Ã°£À¸·Î RESPIROMETRIC Sensor ÀÇ µ¥ÀÌÅͰ¡ Wireless Databox¢â ·Î Àü¼ÛÀÌ µÇ°í ´Ù½Ã ÀÌ Databox¢â ÀÇ µ¥ÀÌÅÍ´Â LAN À» ÅëÇØ PC ÀÇ RESPIROSoft¢â ·Î
Àü¼ÛµÇ¾î À¯¿ëÇÑ µ¥ÀÌÅÍ·Î ½Ç½Ã°£ ÀüȯµÇ°Ô µÈ´Ù.
RESPIROMETRIC Sensor System Maxi 6 - BMP
RESPIROMETRIC Sensor System Maxi 6 - BMP ´Â ¸Þź (CH©þ) °¡½º ¹ß»ýÁ¤µµ¸¦ ÃøÁ¤ÇÏ´Â RESPIROMETRIC Sensor ½Ã½ºÅÛÀÌ´Ù.
Çø±â¼ºÇÏ¿¡¼ Çø±â¼º¹Ì»ý¹°ÀÌ Biomass ¸¦ ºÐÇØÇÏ¿© È£ÈíÇÒ ¶§ ¸Þź (CH©þ) °¡½º¿Í CO©ü °¡ »ý¼ºµÇ´Âµ¥ ¹ß»ýµÈ CO©ü ´Â RESPIROMETRIC Sensor ¿¡ ÀåÂøµÇ¾î ÀÖ´Â
Alkali Hold ¿¡ ÀÇÇØ Èí¼öµÇ¾î Á¦°ÅµÇ°í ¿ë±â¾È¿¡´Â ¹Ì»ý¹°¿¡ ÀÇÇØ »ý¼ºµÈ ¸Þź °¡½ºÀÇ ¾ç¸¸Å ¾Ð·ÂÀÌ Áõ°¡ÇÏ°Ô µÈ´Ù.
ÀÌ·¯ÇÑ ¾Ð·ÂÀÇ ¹Ì¼¼ º¯È¸¦ RESPIROMETRIC Sensor °¡ ÃøÁ¤ÇÏ¿© BMP ´ÜÀ§ÀÎ NmlCH4/gSV °ªÀ¸·Î °è»êÇÏ¿©ÁØ´Ù.
RESPIROMETRIC Sensor ´Â ÃøÁ¤µÈ BOD °ªÀ» ¼³Á¤µÈ ½Ã°£ °£°ÝÀ¸·Î Databox¢â ¸¦ ÅëÇØ PC ÀÇ RESPIROSoft¢â ·Î Àü¼ÛÇϸç
¶ÇÇÑ ¿ÍÀÌÆÄÀ̸¦ ÀÌ¿ëÇϸé Databox¢â ¿¡¼ VELP »çÀÇ ½ÇÇè µ¥ÀÌÅÍ Å¬¶ó¿ìµå Platform ÀÎ ERMES ·Î µ¥ÀÌÅ͸¦ Àü¼ÛµÇ¾î ÀúÀåÀÌ °¡´ÉÇÏ´Ù. |
|
Manometric BMP Measurement Method
¿ë±â³»¿¡¼ ¹Ì»ý¹°¿¡ ÀÇÇØ ¸Þź°¡½º°¡ Áõ°¡Çϸé
--> »ý¼ºµÈ ¸Þź°¡½º ¾ç¸¸Å ¿ë±â³»ÀÇ ¾Ð·ÂÀÌ Áõ°¡ÇϹǷÎ
--> ¿ë±â³» ¾Ð·ÂÀÇ º¯È¸¦ ÃøÁ¤ÇÏ¿©
--> ÀÚµ¿À¸·Î BMP °ª (NmlCH4/gSV) À¸·Î ȯ»êÇÏ¿© Ç¥½Ã |
|
|
Manometric Method ´Â °øÀÎµÈ BMP ºÐ¼® ±â¹ýÀ¸·Î¼ Àü¼¼°è¿¡¼ ³Î¸® »ç¿ëµÇ°í ÀÖ½À´Ï´Ù. |
|
|
Wireless Data Transferring
Wireless Data Transferring ±â´ÉÀ» °¡Áø RESPIROMETRIC Sensor ¿¡ ÀÇÇØ ¿ë±â³»
BMP °ªÀÌ ½Ç½Ã°£À¸·Î DataBox¢â ·Î ¹«¼± Àü¼ÛµÇ¾î ÀÌ µ¥ÀÌÅͰªÀÌ ÄÄÇ»ÅÍÀÇ
RESPIROSoft¢â ÇÁ·Î±×·¥¿¡ ½Ç½Ã°£À¸·Î ³ªÅ¸³ª´Â ±â´ÉÀ» °¡Áø BMP ÃøÁ¤ ÀåÄ¡ |
|
|
- DataBox¢â ¿Í RESPIROSoft¢â software ´Â ±âº»À¸·Î   System ¿¡ Æ÷ÇÔ |
|
|
Velp »çÀÇ ERMES Cloud Platform ¿¡ Connection
RESPIROMETRIC Sensor System À» VELP »çÀÇ ½ÇÇè µ¥ÀÌÅÍ
Ç÷§ÆûÀÎ ERMES ¿¡ ¿¬°áÇÒ ¼ö ÀÖ½À´Ï´Ù. |
|
|
- ½ÇÇè µ¥ÀÌÅ͸¦ ¾ðÁ¦ ¾îµð¼´øÁö ½Ç½Ã°£À¸·Î È®ÀÎ °¡´É |
|
|
- PC, tablet ±×¸®°í ½º¸¶Æ®Æù µî ¸ðµç ÀåÄ¡¿¡¼ ½ÇÇè µ¥ÀÌÅÍ È®ÀÎ |
|
|
BMP °ªÀº NmLCH4/gSV ¶Ç´Â ¾Ð·Â (mbar) À¸·Î Ç¥½Ã |
|
|
DataBox¢â ´Â 400 °³ÀÇ RESPIROMETRIC Sensors (66°³ÀÇ System) ÀÇ µ¥ÀÌÅ͸¦ ÀúÀå °¡´É |
|
|
RESPIROMETRIC Sensor System Maxi 6 - BMP includes..
* 6x RESPIROMETRIC Sensor
* DataBox¢â and RESPIROSoft¢â software.
* Maxi Stirring Station 6
* 6x 1000ml glass bottle
* 6x Stirring Bar |
|
|
|
NUMBER OF SENSORS PER SYSTEM |
|
6 |
|
SENSOR DISPLAY |
|
4 LED digits |
|
MEASUREMENT |
|
Electronic pressure sensor |
|
TEST TYPOLOGY |
|
BMP |
|
PRESSURE RANGE |
|
500 ~ 2000 mbar (hPa) |
|
BOTTLE VOLUMES |
|
1000 ml |
|
DATABOX SENSOR CAPACITY |
|
Up to 400 REPIROMETRIC Sensor |
|
DATABOX POWER SUPPLY |
|
USB / Plug |
|
CONNECTIVITY |
|
Ermes via Wi-Fi / RESPIROSoft¢â via USB |
|
SAMPLING TIME |
|
From 30m to 48h, depending on the test duration |
|
MEASURING PERIOD |
|
From 1 to 730 days |
|
DATA STORAGE |
|
On sensor, RESPIROSoft¢â Database, Ermes Cloud |
|
SENSOR CONSTRUCTION MATERIAL |
|
Technopolymer |
|
SENSOR DIMENSIONS (WXHXD): |
|
50 x 70 x 70 mm |
|
SENSOR POWER |
|
2 W |
|
SENSOR BATTERY TYPE |
|
CR 2430 |
|
STIRRING STATION POWER SUPPLY |
|
230V / 50-60Hz |
|
STIRRING STATION DIMENSIONS (WXHXD) |
|
432 x 300 x 165 mm |
|
WEIGHT |
|
Sensor : 80g     Stirring Station : 3Kg |
|
SAFETY CLASS |
|
IEC/EN61010-1 |
|
PROTECTION DEGREE |
|
IP 54-EN 60529 |
|
OFFICIAL REFERENCES |
|
ISO 11734 (1995) Water quality
- Evaluation of the utlimate anaerobic biodegradability
  of organic compound in digested sludge
- Method by measuring biogas production |
|
|