Phone
  ´ëÇ¥ÀüÈ­ 1577-7956  
  º»     »ç 031-457-9187  
  ´ë     Àü 042-932-1265

Web Site Visitors
  Today 547    
  Yesterday 768    
  Since 2006 2,077,513    


¿µÁøÄÚÆÛ·¹ÀÌ¼Ç Á¾ÇÕÄ«´Ù·Î±×


The VELP RESPIROMETRIC Sensor is a reliable, versatile, and cloud-enabled instrument for aerobic and anaerobic respiration tests. Learn how a compact and easy-to-use solution enables a wide range of analysis when combined with the specific kit.





µðÀÚÀÎÀÌ compact Çϰí, »ç¿ëÀÌ ¸Å¿ì Æí¸®Çϰí, ´Ù¾çÇÑ ¸ñÀûÀ¸·Î »ç¿ë °¡´ÉÇÑ VELP Respirometric Sensor ´Â Ź¿ùÇÑ ¼º´É°ú °íµµÀÇ »ý»ê¼ºÀ» ÇÊ¿ä·Î ÇÏ´Â ½ÇÇè½Ç¿¡ ÃÖÀûÀÇ ¼±ÅÃÀÔ´Ï´Ù.

RESPIROMETRIC Sensor ´Â °­·ÂÇÑ ¾Ð·Â ÃøÁ¤ ¼¾¼­·Î¼­, VELP º´¿¡ ¼Õ½±°Ô ÀåÂøÇÒ ¼ö ÀÖÀ¸¸ç, Àü¿ë ºÐ¼® ŰƮ¿Í ÇÔ²² »ç¿ëÇÏ¸é ´ÙÀ½°ú °°Àº ´Ù¾çÇÑ È£±â¼º ¹× Çø±â¼º ºÐ¼®À» ¼öÇàÇÒ ¼ö ÀÖ½À´Ï´Ù.
 
BOD (Biochemical Oxygen Demand)
Biodegradability of plastics in an aqueous medium and soil
Soil respiration
BMP (Biochemical Methane Potential)
Denitrification analysis, and more ...

RESPIROMETRIC Sensor ´Â °­·ÂÇÑ ¼º´ÉÀÇ RESPIROSoft¢â ¼ÒÇÁÆ®¿þ¾î¸¦ ÅëÇØ °ü¸®µÇ¸ç, óÀ½ »ç¿ëÇÏ´Â »ç¶÷µµ ½±°Ô »ç¿ëÇÒ ¼ö ÀÖ½À´Ï´Ù. ÀÌ ¼ÒÇÁÆ®¿þ¾î´Â »ç¿ëÀÚ¿¡°Ô ´ÙÀ½°ú °°Àº ±â´ÉÀ» Á¦°øÇÕ´Ï´Ù
ºÐ¼® °î¼±À» ½Ç½Ã°£À¸·Î ¸ð´ÏÅ͸µ
µð½ºÇ÷¹ÀÌ¿¡¼­ ÁÖ¿ä Á¤º¸¸¦ È®ÀÎ
¼¾¼­ ¹èÅ͸® »óÅ ¸ð´ÏÅ͸µ
»çÀü ¼³Ä¡µÈ ºÐ¼® ¹æ¹ý °Ë»ö ¹× »ç¿ë
Å×½ºÆ® º¸°í¼­ ¸ÂÃã ¼³Á¤
°á°ú ºñ±³ ±â´É Á¦°ø

ºÐ¼® À¯Çü¿¡ µû¶ó °á°ú´Â ´ÙÀ½°ú °°Àº ÃøÁ¤ ´ÜÀ§·Î Á¦°øµË´Ï´Ù
BOD (mg/L)
BMP (NmLCH©þ/gSV)
¾Ð·Â (mbar)

¿ë±â¿¡ ÀÖ´Â RESPIROMETRIC Sensor ¿¡¼­ ÃøÁ¤µÈ µ¥ÀÌÅ͵éÀº Çõ½ÅÀûÀÎ Wireless DataBox¢â ¸¦ ÅëÇØ PC ÀÇ RESPIROSoft¢â ¼ÒÇÁÆ®¿þ¾î¿Í ¿¬°áµÇ´Âµ¥ ÀÌ·¯ÇÑ ¿¬°áÀ» ÅëÇØ ´ÙÀ½°ú °°Àº ÀÛ¾÷ÀÌ °¡´ÉÇÕ´Ï´Ù:
ºÐ¼® Á¶°Ç¿¡ ¿µÇâÀ» ÁÖÁö ¾Ê°í, Àåºñ¸¦ Á÷Á¢ È®ÀÎÇÏÁö ¾Ê°íµµ ½Ç½Ã°£À¸·Î ºÐ¼®À» Á¦¾î
ÃÖ´ë 48°³ÀÇ ¼¾¼­ (8°³ÀÇ ±³¹Ý ½ºÅ×À̼Ç) ¿Í 2´ëÀÇ FOC 200 Connect ¸¦ µ¿½Ã¿¡ ¿¬°á
ÀÌÁ¦ Çõ½ÅÀûÀÎ VELP RESPIROMETRIC Sensor ·Î ¼öÇàÇÒ ¼ö ÀÖ´Â ´Ù¾çÇÑ ºÐ¼®À» ÇÔ²² »ìÆìº¸¼¼¿ä!


Aerobic Respirometric Determination
Aerobic Respiration Àº ¹Ì»ý¹°ÀÌ »ê¼Ò°¡ Á¸ÀçÇϴ ȯ°æ¿¡¼­ À¯±â¹°À» ÀÌ»êȭź¼Ò (CO©ü) ·Î ºÐÇØÇÏ´Â »ý¹°ÇÐÀû °úÁ¤ÀÔ´Ï´Ù. VELP RESPIROMETRIC Sensor ¸¦ ÀÌ¿ëÇÏ¿© ´ÙÀ½°ú °°Àº ºÐ¼®À» ¼öÇàÇÒ ¼ö ÀÖ½À´Ï´Ù
»ýÈ­ÇÐÀû »ê¼Ò ¿ä±¸·® (BOD) : ¼öÁú ³» À¯±â ¿À¿°µµ¸¦ ºÐ¼®ÇÏ´Â µ¥ »ç¿ë
Biodegradation of Monomers : ÇÃ¶ó½ºÆ½ »ý»ê¿¡ »ç¿ëµÇ´Â monomers ¿Í polymers ÀÇ biodegradability ¸¦ Æò°¡
Biodegradability of plastic materials in an aqueous medium : ÷°¡Á¦¸¦ Æ÷ÇÔÇÑ ÇÃ¶ó½ºÆ½ ¼ÒÀçÀÇ aerobic biodegradability Á¤µµ¸¦ ÃøÁ¤
Biodegradability of plastic materials in the soil : Åä¾ç ³» ÀûÀýÇÑ ¼öºÐÀ» À¯ÁöÇϸç ÇÃ¶ó½ºÆ½ ¼ÒÀçÀÇ ÃÖÁ¾ »ýºÐÇØµµ¸¦ ÃøÁ¤ÇÏ¿© ÃÖÀûÀÇ ºÐÇØ ¼Óµµ¸¦ È®ÀÎ
Soil respiration : Åä¾çÀÇ »ý¹°ÇÐÀû Ȱµ¿ ¼öÁØ, À¯±â¹° ÇÔ·®, ºÐÇØ Á¤µµ¸¦ ³ªÅ¸³»´Â Áß¿äÇÑ ÁöÇ¥·Î, ½ÇÇè½Ç¿¡¼­´Â Åä¾ç ¹Ì»ý¹°·®À» ÃßÁ¤ÇÏ´Â µ¥ »ç¿ë


Anaerobic Respirometric Determination
Çø±â¼º È£ÈíÀº ¹Ì»ý¹°ÀÌ »ê¼Ò°¡ ¾ø´Â ȯ°æ¿¡¼­ À¯±â¹°À» ºÐÇØÇÏ¿© ¹ÙÀÌ¿À°¡½º¸¦ »ý¼ºÇÏ´Â »ý¹°ÇÐÀû °úÁ¤ÀÔ´Ï´Ù. VELP RESPIROMETRIC Sensor ¸¦ ÅëÇØ ´ÙÀ½°ú °°Àº ºÐ¼®À» ¼öÇàÇÒ ¼ö ÀÖ½À´Ï´Ù
Biochemical Methane Potential Determination -- BMP
À¯±â Æó±â¹°ÀÇ ¹ÙÀÌ¿À ¸Þź »ý¼º °¡´É¼ºÀ» Æò°¡ÇÏ¿©, ´ÜÀ§ ¹«°Ô´ç »ý¼º °¡´ÉÇÑ ¹ÙÀÌ¿À°¡½º ¶Ç´Â ¸ÞźÀÇ ¾çÀ» ÃøÁ¤ÇÕ´Ï´Ù. ÀÌ´Â À¯±â Æó±â¹°À» Àç»ý °¡´É ¿¡³ÊÁö·Î ÀüȯÇϱâ À§ÇÑ ÀûÀýÇÑ ¾çÀ» °áÁ¤ÇÏ´Â µ¥¿¡µµ À¯¿ëÇÕ´Ï´Ù.
Denitrification analysis
Åä¾ç¿¡ Á¸ÀçÇÏ´Â Anaerobic Denitrifying Bacteria (Çø±â¼º Å»Áú ¼¼±Õ) ¿¡ ÀÇÇØ Áú»ê¿° (NO©ý?) °ú ¾ÆÁú»ê¿° (NO©ü?) ÀÌ ºñºñ·á¼º È­ÇÕ¹°·Î ȯ¿øµÇ´Â °úÁ¤ÀÔ´Ï´Ù. ÀÌ ¹ÝÀÀÀº COD/N ºñÀ² (È­ÇÐÀû »ê¼Ò ¿ä±¸·®°ú Á¦°ÅÇØ¾ß ÇÒ Áú»ê¿° ³óµµÀÇ ºñÀ²) À» Á¤ÀÇÇÏ´Â µ¥ »ç¿ëµË´Ï´Ù.
ÀÌ Å×½ºÆ®¸¦ ¼öÇàÇϱâ À§Çؼ­´Â ½Ã½ºÅÛÀ» ¾÷±×·¹À̵åÇÏ¿© ´ÙÀ½ÀÇ ¼±Åà »ç¾çÀ» Ãß°¡ÇØ¾ß ÇÕ´Ï´Ù
- code A00000410 - 1000 ml clear bottle with the lateral neck



 
(ÁÖ)¿µÁøÄÚÆÛ·¹ÀÌ¼Ç   |   ´ëÇ¥ : ÀÌÇü¿­   |   »ç¾÷ÀÚµî·Ï¹øÈ£ : 138-81-34745
±º Æ÷ º» »ç   |   (15853) °æ±âµµ ±ºÆ÷½Ã ÇѼ¼·Î 48 ³²¿øºôµù 2Ãþ   |   ÀüÈ­ : 1577-7956 (1)   |   ÆÑ½º : 031-457-9188   |   À̸ÞÀÏ : info@yjcorp.co.kr
´ë Àü Áö »ç   |   (34036) ´ëÀü½Ã À¯¼º±¸ Å×Å©³ë10·Î 29 ÆÄÅ©ÆÓ¸®½º 2Ãþ   |   ÀüÈ­ : 1577-7956 (2)   |   ÆÑ½º : 042-932-1266   |   À̸ÞÀÏ : info@yjcorp.co.kr