LumiReader Separation Analyser
LumiReader Separation Analyser
Tilt Technology in LumiReader
Cat. No.
LR 4532-100, LUMiReader PSA Separation Analyzer °ßÀû¿äû

ÀÏ¹Ý Áß·ÂÇÏÀÇ ÀÚ¿¬Ä§°­ Á¶°Ç¿¡¼­ ƯÇã¹ÞÀº ºÐ¼® ±â¼úÀÎ STEP Technology¢ç ¸¦ ÀÌ¿ëÇÏ¿© ºÐ»êµÈ ¹°ÁúÀÇ ºÐ»ê¾ÈÁ¤¼º ºÐ¼®°ú ÀÔµµºÐ¼® (particle sie distribution) À» °¡´ÉÇÏ°Ô ÇÏ´Â separation analyser

ºÐ»ê.À¯È­µÈ ¹°ÁúÀÌ ÀÚ¿¬Áß·ÂÇÏ¿¡¼­ sedimentation / creaming µÇ´Â Çö»óÀ» Åõ°úµµ¸¦ ÀÌ¿ëÇÏ¿© ÃøÁ¤ÇÏ´Â Àåºñ
±ÙÀû¿Ü¼± (NIR) ÀÌ sample À» Åõ°úÇÏ´Â Á¤µµ Áï ¼öõ°³ÀÇ ¼¾¼­¸¦ ÀÌ¿ëÇÏ¿© Åõ°úµµ (transmission) ¸¦ ÃøÁ¤ÇÏ´Â Åõ°úµµÀÇ º¯È­¸¦ ºÐ¼®ÇÏ¿© ºÐ»ê¾ÈÁ¤¼º°ú ÀÔµµ¸¦ ºÐ¼®ÇÏ´Â Àåºñ
°¢ sample µéÀÇ Åõ°úµµ º¯È­ (transmission profile) ¸¦ ÃøÁ¤ÇÑ ÈÄ ÀÌ Ãʱ⠵¥ÀÌÅÍ·Î ºÎÅÍ °¢ sample ÀÇ ¾ÈÁ¤¼ºÁö¼ö (stability index) ¸¦ ºÐ¼®ÇÏ¿© sample °£ÀÇ ºÐ»ê.À¯È­ Á¤µµ¸¦ ºñ±³ ºÐ¼®
´Ù¾çÇÑ ÇüÅÂÀÇ ºÐ»ê¾ÈÁ¤¼º °ü·Ã Áö¼ö¸¦ ÀÌ¿ëÇÏ¿© °¢ sample ÀÇ ºÐ»ê ¾ÈÁ¤¼º ºÐ¼®
Clarification velocity, sedimentation and floatation velocity, residual turbidity, separated phase volume, sediment consolidation, dewaterability ¿Í °°Àº ºÐ»êÈÄÀÇ ´Ù¾çÇÑ demixing Çö»ó¿¡ ´ëÇÑ Á¤·®È­ °¡´É
LumiReader ¿¡ ÀåÂøµÈ PSD (particle size distribution) module À» ÀÌ¿ëÇÏ¿© ÀÔµµ ºÐ¼®ÀÌ °¡´É
reflection index (±¼Àý·ü), density (¹Ðµµ) ¿Í °°Àº parameter ¸¦ ÀÔ·ÂÇÏÁö ¾Ê¾Æµµ ÀÔÀÚµéÀÇ velocity distribution ÃøÁ¤°ú ºÐ¼®ÀÌ °¡´É
±¼Àý·ü°ú ¹Ðµµ¸¦ ÀÔ·ÂÇϸé volume-weighted particle size distribution À» ±¸ÇÒ ¼ö ÀÖ´Ù.
LumiReader PSA ¿¡ ÀÇÇÑ ÀÔµµ ºÐ¼®°ªÀº ÀÏ¹Ý ·¹ÀÌÀúȸÀý¹ý µî°ú °°Àº ºÐ¼®¹ý°ú µ¿ÀÏÇÑ µ¥ÀÌÅÍ
Tilt Technology
tube ÀÇ ±â¿ï±â¸¦ ÃÖ´ë 30µµ ±îÁö ±â¿ïÀ̸é tube ³»ºÎ¿¡¼­ ħ°­ÇÏ´Â ¹°ÁúÀÇ Ä§°­¼Óµµ´Â ±×¿¡ ºñ·ÊÇÏ¿© Áõ°¡ÇÑ´Ù´Â ÀÌ·Ð
LumiReader PSA ´Â Tilt Technology ¸¦ Àû¿ëÇÏ¿© ÀÏ¹Ý Áß·ÂÇÏ¿¡¼­ÀÇ Ä§°­¼Óµµº¸´Ù ÃÖ´ë 10¹è ºü¸¥ ħ°­ÀÌ °¡´ÉÇÏ¿© ÃøÁ¤¼Óµµ°¡ ºü¸£´Ù.


  Accelerated phase separation   up to 10 times at gravity
  Test time reduction through sensitivity   up to 250 times
  Particle size distribution   500 nm to 300 ¥ìm
  Observation time   0.5 s to unlimited
  Conformity   ISO/TR 13097; ISO 13317; ASTM D7827; CFR 21 Part 11
  Samples   1 sample
  Volume   0.5 ml to 4.0 ml
  Concentration   0.00015 Vol% to 75 Vol%
  Density   up to 22 g/cm©ø
  Particle size   200 nm to 2000 ¥ìm
  Light source   multi-wavelength
  Temperature control   ambient +3 ¡Æc to 60 ¡ÆC, +/? 1K
  Tilt   vertical to 5¡Æ, 10¡Æ, 15¡Æ, 20¡Æ, 25¡Æ, 30¡Æ
  Cells   different material and optical path
  Dimensions (WxHxD)   29 x 24 x 44 cm
  Weight   11 kg
  Power supply   24 V, Adapter (100 V to 240 V) included





 