DC-23D Standard Portable Spectrophotometer |
|
Superior Inter-Instrument Consistency and Instrument Repeatability |
 | |
| |
| DC-23D Portable Spectrophotometer | |
| |
 | |
| |
| DC-23D Portable Spectrophotometer | |
| |
 | |
| |
| Excellent Inter-Instrument Consistency | |
| |
 | |
| |
| Industry-leading wavelength range :360-780nm | |
| |
 | |
| |
| Integrating Sphere with Dual Lighting Source | |
| |
 | |
| |
| Silicon Photodiode Array Sensor | |
| |
 | |
| |
| BCRA Green Board for Auto. Calibration | |
| |
 | |
| |
| 6 kinds of Measuring Apertures : DC-25D | |
| |
|
|
| Cat. No. |
| |
| DC-23D Portable Spectrophotometer |
Á¦Ç°¹®ÀÇ |
| |
| ÀÌ ¸ðµ¨Àº ÈÞ´ë¿ëÀÌ°í °¡°ÝÀº Àú·ÅÇÏÁö¸¸ ¥ÄE*ab °¡ ¡Â0.02, ±â±â°£ ¥ÄE*ab ´Â ¡Â0.25 ·Î ÀçÇö¼ºÀÌ ¸Å¿ì Ź¿ùÇϸç
auto-calibration µî ´Ù¾çÇÑ Ã·´Ü±â´ÉÀÌ ÀåÂøµÈ ÃÖ°í ¼º´ÉÀÇ High-End ±Þ»ö±òÃøÁ¤ (Ãø»ö, ö´ßä) ÀåºñÀÔ´Ï´Ù.
¶ÇÇÑ High-end ±Þ ÀåºñÀÎ DS-36D ¸ðµ¨ °ú ±â±â°£ ÃøÁ¤°ª ÀÏÄ¡¼ºÀÌ °¡Àå Ź¿ùÇÑ ¸ðµ¨ÀÔ´Ï´Ù. |
| ¡á |
ÃøÁ¤°ª ÀçÇö¼º°ú ±â±â°£ ÃøÁ¤°ª ÀÏÄ¡¼ºÀÌ ¸Å¿ì Ź¿ù |
| |
µ¿ÀÏÇÑ »ùÇÃÀ» ¿©·¯ ¹ø ÃøÁ¤ÇÏ¿´À» ¶§ÀÇ ÃøÁ¤°ª ÀçÇö¼ºÀÎ ¥ÄE*ab (»öÂ÷°ª Ç¥ÁØÆíÂ÷) ´Â ¡Â0.02,  
±â±â°£ ÃøÁ¤°á°ú ÀÏÄ¡¼ºÀº ¡Â0.25 ·Î¼ ÈÞ´ë¿ëÀ¸·Î »ç¿ëµÇ´Â Ÿ»ç Àåºñº¸´Ù Á¤¹Ðµµ°¡ ÈξÀ Ź¿ùÇÕ´Ï´Ù. . |
|
| ¡á |
µ¿±Þ Àåºñ Áß °¡Àå ³ÐÀº ÆÄÀå ¹üÀ§, 360 ~ 740nm |
| |
ÀϹÝÀûÀΠŸ»ç Ãø»öÀåºñµé°ú ´Þ¸® CHNSpec »ç ´ëºÎºÐÀÇ Spectrophotometer ´Â
360 - 740nm·Î È®ÀåµÈ ÆÄÀå ´ë¿ªÀ» »ç¿ëÇÏ¿© ´ÙÀ½°ú °°Àº ÀåÁ¡À» °¡Áö°í ÀÖ½À´Ï´Ù. |
|
| |
| • |
Çü±¤Áõ¹éÁ¦ (OBA) ÃøÁ¤ °¡´É (360nm ¿µ¿ª) : DC-23D ´Â Àڿܼ±(UV) ÀÎÁ¢ ¿µ¿ª (360nm~) À» Æ÷ÇÔÇϰí ÀÖ¾î Çü±¤Áõ¹éÁ¦°¡
Æ÷ÇÔµÈ ½Ã·áÀÇ ¹é»öµµ(Whiteness Index) ¸¦ ÈξÀ Á¤¹ÐÇÏ°Ô ÃøÁ¤ÀÌ °¡´É |
|
| • |
»ö»óÀÇ Ç¥Çö ¹üÀ§(Color Gamut) ¹× Á¤¹Ðµµ Çâ»ó : °¡½Ã±¤¼±ÀÇ ¾ç ³¡´ÜÀÎ º¸¶ó»ö (´ÜÆÄÀå 360nm~) °ú ÁøÇÑ »¡°£»ö (740nm) ¿µ¿ªÀÇ
µ¥ÀÌÅ͸¦ ´õ È®º¸°¡ °¡´ÉÇÏ°Ô µÇ¹Ç·Î ¹Ý»çÀ² °î¼± (Spectral Reflectance Curve) ÀÌ ´õ ¸Å²ô·´°í Á¤È®ÇÏ°Ô ±×·ÁÁý´Ï´Ù.
ƯÈ÷ ÁøÇÑ ³²»öÀ̳ª ¾ÆÁÖ ±íÀº ºÓÀº»ö °è¿À» ÃøÁ¤ÇÒ ¶§ 400 - 700nm Àåºñº¸´Ù µ¥ÀÌÅÍÀÇ ¿Ö°îÀÌ Àû¾îÁý´Ï´Ù. |
|
| • |
´Ù¾çÇÑ ±¹Á¦ Ç¥ÁØ ¹× Áö¼ö ´ëÀÀ : ¸¹Àº »ê¾÷ Ç¥ÁØ (ASTM, ISO µî) ¿¡¼ Àüü °¡½Ã±¤ ¿µ¿ªÀÇ µ¥ÀÌÅ͸¦ ¿ä±¸Çϴµ¥
ÀÌ´Â ÆÄÀå ¹üÀ§°¡ ³ÐÀ»¼ö·Ï ´Ù¾çÇÑ »öä Áö¼ö (Yellowness, Whiteness µî) ¸¦ °è»êÇÒ ¶§ ¿ÀÂ÷°¡ ÁÙ¾îµé±â ¶§¹®ÀÔ´Ï´Ù.
ƯÈ÷ ¿°·á³ª ¾È·á¸¦ ´Ù·ç´Â ÈÇÐ, ÆäÀÎÆ®, ¼¶À¯ »ê¾÷¿¡¼´Â ÀÌ Á¼Àº Â÷À̰¡ ¸ÞŸ¸Þ¸®Áò (Metamerism, Á¶°Çµî»ö) Çö»óÀ» ºÐ¼®ÇÏ´Â µ¥ Å« µµ¿òÀ» ÁÖ°Ô µË´Ï´Ù. |
|
|
| ¡á |
Dual Lighting Source (ÀÌÁß ±¤¿ø ½Ã½ºÅÛ) |
| |
| ÀϹÝÀûÀ¸·Î Ãø»ö°è´Â Á¦³í ·¥ÇÁ¸¸ ¾²°Å³ª LED ¸¸ »ç¿ëÇϴµ¥, CHNSpec »ç ´ëºÎºÐ Spectrophotometer ´Â Xenon Lamp + LED µÎ °¡Áö¸¦ ¸ðµÎ »ç¿ëÇÕ´Ï´Ù. |
|
| Á¦³í ·¥ÇÁ´Â °·ÂÇÑ ¿¡³ÊÁö¸¦ ³»¾î UV (Àڿܼ±) ¿µ¿ª±îÁö Ä¿¹öÇϰí, LED´Â °¡½Ã±¤¼± ¿µ¿ª¿¡¼ ¾ÈÁ¤ÀûÀÎ ºûÀ» Á¦°øÇÕ´Ï´Ù. |
|
| µÎ ±¤¿øÀ» °áÇÕÇØ ÃøÁ¤¿¡ ÇÊ¿äÇÑ Àü ¿µ¿ª (UV + °¡½Ã±¤¼±) ÀÇ ¿¡³ÊÁö¸¦ ÃæºÐÈ÷ È®º¸Çϰí ÀÖ´Ù´Â °ÍÀ» ÀǹÌÇÕ´Ï´Ù. |
|
|
| ¡á |
¼öõ¸¸ ¹ø ÃøÁ¤ÀÌ °¡´ÉÇÑ ¼ö¸í |
| |
ÀÌ Àåºñ´Â Dual Light Source SystemÀ» »ç¿ëÇϹǷΠÀÏ¹Ý ·¥ÇÁ¿¡ ºñÇØ ÈξÀ ´õ ¿À·§µ¿¾È ·¥ÇÁ ±³Ã¼ ¾øÀÌ »ç¿ëÀÌ °¡´ÉÇÕ´Ï´Ù.
|
| • |
ºÎÇÏÀÇ ºÐ»ê (Load Balancing)
: °¡½Ã±¤¼± ¿µ¿ªÀº ¼ö¸íÀÌ ¸Å¿ì ±ä LED°¡ ´ã´çÇϰí, °·ÂÇÑ ¿¡³ÊÁö°¡ ÇÊ¿äÇÑ UV ¿µ¿ª µîÀº Á¦³í ·¥ÇÁ°¡ º¸Á¶ÇÏ´Â ±¸Á¶À̹ǷÎ
±¤¿ø Çϳª¿¡ °¡ÇØÁö´Â ½ºÆ®·¹½º°¡ ÁÙ¾îµé¾î Àüü ½Ã½ºÅÛ ¼ö¸íÀÌ ´Ã¾î³ª°Ô µË´Ï´Ù. |
|
| • |
LEDÀÇ ¾ÐµµÀûÀÎ ¼ö¸í
: ½Ã½ºÅÛÀÇ »ó´ç ºÎºÐÀ» Â÷ÁöÇÏ´Â °¡½Ã±¤¼± ±¤¿øÀ» ´ã´çÇÏ´Â LED ´Â ¹ÝµµÃ¼ ¹æ½ÄÀ̶ó ¼ö¸íÀÌ ¹Ý¿µ±¸ÀûÀÔ´Ï´Ù. |
|
| • |
¹ß¿ °¨¼Ò (Heat Management)
: µà¾ó ±¤¿ø ½Ã½ºÅÛÀ» ÅëÇØ Á¦³í ·¥ÇÁÀÇ °¡µ¿ ºñÁßÀ» ÃÖÀûÈÇϹǷΠÀåºñ ³»ºÎÀÇ ¹ß¿ÀÌ ³·¾ÆÁö°í, °á°úÀûÀ¸·Î ±¤¿ø»Ó¸¸ ¾Æ´Ï¶ó Àåºñ
ÀüüÀÇ Service Life (»ç¿ë ¼ö¸í) °¡ ±æ¾îÁö°Ô µË´Ï´Ù. |
|
|
| ¡á |
NetProf Network Calibration |
| |
|
| ÀÌ Àåºñ¿¡ ³»ÀåµÈ NetProf Áö´ÉÇü Calibration ½Ã½ºÅÛÀ» ÀÌ¿ëÇϸé ÀÎÅͳÝÀ» ÅëÇØ º»»çÀÇ ¼¹ö (Cloud/Network) ¿¡ µî·ÏµÈ Ç¥ÁØ µ¥ÀÌÅÍ¿Í ³» ÀåºñÀÇ ÇöÀç »óŸ¦ ºñ±³ÇÒ ¼ö ÀÖ½À´Ï´Ù |
|
| ¸¸¾à ÀåºñÀÇ ³ëÈÄÈ·Î ÀÎÇØ ¹Ì¼¼ÇÑ ¿ÀÂ÷°¡ ¹ß°ßµÇ¸é, ¼ÒÇÁÆ®¿þ¾î°¡ ±× Â÷À̸¸ÅÀ» ¿¬»ê °úÁ¤¿¡¼ ÀÚµ¿À¸·Î º¸Á¤ÇÏ¿© Ç×»ó »õ Àåºñ¿Í µ¿ÀÏÇÑ ¼öÁØÀÇ °á°ú°ªÀ» ³»º¸³» ÁÖ°Ô µË´Ï´Ù. |
|
| »ç¿ëÀÚ°¡ ¸Å¹ø º¹ÀâÇÑ °è»êÀ» Çϰųª ºÎǰÀ» °¥ ÇÊ¿ä ¾øÀÌ, Á¤±âÀûÀ¸·Î Á¦°øµÇ´Â °¡À̵忡 µû¶ó ±³Á¤ (Calibration) °úÁ¤¸¸ °ÅÄ¡¸é ¼ÒÇÁÆ®¿þ¾î°¡ ¾Ë¾Æ¼ ¿ÀÂ÷°ªÀ» °è»êÇϰí Àû¿ëÇϱ⠶§¹®¿¡ »ç¿ëÀÌ ¸Å¿ì Æí¸®ÇÕ´Ï´Ù. |
|
|
| ¡á |
2°¡Áö Á÷°æÀÇ ÃøÁ¤±¸ (Measuring Apertures) |
| |
¨ª11mm ¿Í ¨ª6mm 2°¡Áö Å©±âÀÇ ºûÀÌ ³ª°¡´Â ±¸¸Û, Áï ÃøÁ¤±¸ (Measuring Aperture) °¡ ±âº»À¸·Î °ø±ÞµË´Ï´Ù.
- ¨ª11mm : ÆòÆòÇÏ°í ³ÐÀº ¸éÀû¿¡ ÀûÇÕ
- ¨ª6mm : ±¼°îÀÌ Àְųª ¾ÆÁÖ ÀÛÀº Å©±âÀÇ »ùÇÿ¡ ÀûÇÕ |
|
| ¡á |
BCRA Green Plate ¸¦ ÀÌ¿ëÇÑ Áö´ÉÇü ÀÚµ¿ Calibration |
| |
DC-23D ÀåºñÀÇ Base ¿¡ °¡Àå ±î´Ù·Î¿î ³ì»ö Ç¥ÁØÀÎ BCRA Green Plate ¸¦ ÀåÂøÇϸé Àåºñ´Â ÀÚµ¿À¸·Î
ÇöÀç ºûÀÇ ÆÄÀåÀÌ Á¤È®ÇÑÁö ½º½º·Î È®ÀÎÇÏ°í ¸¸¾à ÆÄÀåÀÌ ±âÁذª¿¡¼ ¹Ì¼¼ÇÏ°Ô ¹þ¾î³ª ÀÖ´Ù¸é,
¼ÒÇÁÆ®¿þ¾î°¡ À̸¦ ÀÚµ¿À¸·Î º¸Á¤ÇÏ´Â Áö´ÉÇö Automatic Calibration ±â´ÉÀ» ÀåÂøÇϰí ÀÖ½À´Ï´Ù. |
|
| ¡á |
Â÷¼¼´ë Photo Array ½Ç¸®ÄÜ ±¤¼¾¼ |
| |
ºûÀ» ÆÄÀ庰·Î ºÐÇØÇÏ¿© °¨ÁöÇÏ´Â ÃÖ½ÅÇü ±¤¼¾¼ÀÎ Silicon Photodiode Array Sensor (½Ç¸®ÄÜ Æ÷Åä´ÙÀÌ¿Àµå ¾î·¹ÀÌ ¼¾¼) °¡ ÀåÂøµÇ¾î ÀÖÀ¸¸ç
¾Æ·¡¿Í °°Àº Ư¡À¸·Î ÀÎÇØ ÀçÇö¼º°ú ±â±â°£ ÀÏÄ¡¼ºÀÌ Å¹¿ùÇÏ°Ô µË´Ï´Ù.
|
| • |
Multi-channel Detection
ȸÀý°ÝÀÚ (Grating) ¸¦ ÅëÇØ ºÐÇØµÈ ¹«Áö°³»ö ºûÀÌ ÀÌ ±¤¼¾¼¿¡ Åõ»çµÇ¸é ¼¾¼ÀÇ ¼ö¸¹Àº °¡°¢ÀÇ ¼¿ÀÌ Æ¯Á¤ ³ª³ë¹ÌÅÍ ¹üÀ§ÀÇ ºûÀ» ´ã´çÇÏ¿© µ¿½Ã¿¡ ÃøÁ¤ÇϹǷÎ,
ÃøÁ¤ ¼Óµµ°¡ ¸Å¿ì ºü¸£°í Á¤¹ÐÇÑ ºÐ±¤ ¹Ý»çÀ² µ¥ÀÌÅ͸¦ ¾òÀ» ¼ö ÀÖ½À´Ï´Ù. |
|
| • |
Superior Sensitivity and Reliability
½Ç¸®ÄÜ ±â¹Ý ¼¾¼´Â °¡½Ã±¤¼± ¿µ¿ª (¾à 400~700nm) ¿¡¼ ¹ÝÀÀ¼ºÀÌ ¸Å¿ì ¶Ù¾î³ª°í ³ëÀÌÁî°¡ Àû½À´Ï´Ù.
¶ÇÇÑ ¼¾¼ÀÇ ¹è¿ÀÌ °íÁ¤µÇ¾î ÀÖ¾î ¿ÜºÎ Ãæ°ÝÀ̳ª Áøµ¿¿¡µµ ÆÄÀå ¿ÀÂ÷°¡ Àû°Ô ¹ß»ýÇÕ´Ï´Ù. |
|
|
|
|
| DC-23D Precise Portable Spectrophotometer Operation Video |
| DC-23D Standard Portable Spectrophotometer Technical Data |
|
| NetProf network calibration |
|
Yes |
|
| Measurement Structure |
|
d/8,   SCI+SCE |
|
| Simultaneous Measurement of SCI+SCE |
|
Yes |
|
| Integrating Sphere Diameter |
|
40mm |
|
| Lighting Source |
|
Full Band balanced LED Light Source + Xenon Lamp |
|
| Detector |
|
Dual-row High-Precision CMOS Array Sensor |
|
| Calibration Mode |
|
BCRA Certified Black and White Board Energy Calibration, Green Board Wavelength Accuracy Calibration |
|
| Spectroscopic Method |
|
Grating |
|
| Display Resolution |
|
0.01 |
|
| Light Source Lifetime |
|
6 Million Times |
|
| Wavelength range |
|
360 - 740nm |
|
| Wavelength Interval |
|
10nm |
|
| Reflectance Measurement Range |
|
0 - 200% |
|
| Reflectance resolution |
|
0.01% |
|
| Caliber |
|
¥Õ11mm, ¥Õ6mm |
|
| Measurement Repeatability (¥ÄE*ab) |
|
¡Â0.02 |
|
| Inter-instrument Consistency |
|
¡Â0.25 |
|
| UV Light Source |
|
Yes |
|
| Field Angle |
|
2¡Æ£¬10¡Æ |
|
| Light Source Condition |
|
A, B, C, D50, D55, D65, D75F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12CWF, U30, U35, DLF, NBF, TL83,T
L84, ID50, ID65, LED-B1, LED-B2, LED-B3, LED-B4LED-B5, LED-BH1, LED-RGB1, LED-V1, LED-V2 |
|
| Measurement Index |
|
- Spectral Reflectance, CIe-LAB, CIE-LCH, HunterLab, CIE-LUv, XYZ,Yxy, RGB Chromatic Aberration (¥ÄE*ab,¥ÄE*cmc,¥ÄE*94,¥ÄE*00),
- Whiteness (ASTM E313-00, ASTM E313-73, CIE, ISO2470 /R457, AATCC, Hunter, Taube BergerStensby),
- Yellowness (ASTM D1925, ASTM E313-00, ASTM E313-73)
- Blackness (My, dM),
- Color Fastness, Colorchange Fastness, Tint (ASTM E313-00)
- Color Density CMYK (A,T,E,M), Isochromatic Index Milm, Munsell, Mask Cap Power, Force (dye strength, coloring power) |
|
| Measuring Time |
|
About 1 sec |
|
| Memory |
|
Instrument : 10,000 records / APP : Mass storage |
|
| Battery Capacity |
|
8000 Continuous Measurements with a single charge, 7.2V/3000mAh |
|
| Measurement and Observation Mode |
|
Camera |
|
| Screen |
|
Full Color Screen, 3.5 inches |
|
| Language |
|
Simplified Chinese, English |
|
| Port |
|
USB, Bluetooth |
|
| Calibration |
|
Intelligent Automatic Calibration |
|
| Software Support |
|
Android, iOS, Windows |
|
| Accuracy Guarantee |
|
Ensure First-Class Measurement Accuracy |
|
| Standard Compliance |
|
CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724-1, ASTM E1164, DIN5033 Teil7 |
|
| Dimension |
|
233mm x 77mm x 93mm |
|
| Weight |
|
~ 600g |
|
|