Phone |
|
|
  ´ëÇ¥ÀüÈ |
1577-7956   |
  º»     »ç |
031-457-9187   |
  ´ë     Àü |
042-932-1265 |
|
|
Web Site Visitors |
|
|
  Today |
109     |
  Yesterday |
747     |
  Since 2006 |
1,941,949     |
|
|
|
|
¿µÁøÄÚÆÛ·¹ÀÌ¼Ç Á¾ÇÕÄ«´Ù·Î±× |
|
|
|
|
|
|
Advanced Programmable Controller |
|
|
|
Advanced Programmable Circulator |
|
|
Cat. No. |
|
AP07R-20-A11B, 7 Liter, -20¡ÆC |
°ßÀû¿äû |
|
AP7LR-20-A11B, 7 Liter, -20¡ÆC, low profile |
°ßÀû¿äû |
|
AP07R-40-A11B, 7 Liter, -40¡ÆC |
°ßÀû¿äû |
|
AP15R-30-A11B, 15 Liter, -30¡ÆC |
°ßÀû¿äû |
|
AP15R-40-A11B, 15 Liter, -40¡ÆC |
°ßÀû¿äû |
|
AP20R-30-A11B, 20 Liter, -30¡ÆC |
°ßÀû¿äû |
|
AP28R-30-A11B, 28 Liter, -30¡ÆC |
°ßÀû¿äû |
|
AP45R-20-A13D, 45 Liter, -25¡ÆC |
°ßÀû¿äû |
|
ÃÖ°íÀÇ ¿Âµµ Á¤¹Ð¼º°ú ÃÖ°íÀÇ ¼º´É, ´Ù¾çÇÑ ÀÀ¿ë¼ºÀ» °¡Áö°í ÀÖ´Â Performance Programmable Temperature Controller ¸¦ ÀåÂøÇÑ ¼øȯ Ç׿ÂÁ¶
(Refrigerated / Heated Circulating Bath) |
|
¡¾0.005¡ÆC ÀÇ Á¤¹ÐÇÑ ¿Âµµ ¾ÈÁ¤¼º |
|
|
Á¦Ç°¿¡ µû¶ó -40¡É ~ +200¡É ÀÇ ¿Âµµ Á¶Àý |
|
|
¿Âµµ¿Í ½Ã°£ ¼³Á¤À» °¹¼ö¿¡ Á¦ÇѾøÀÌ ÀÚÀ¯·ÎÀÌ ¼³Á¤°¡´ÉÇÑ OpenMode time/temperature programming |
|
|
ÀÛµ¿Çϱ⠽¬¿î 4.3ÀÎÄ¡ (10.9cm) Smart Touch Display |
|
|
¼Óµµ Á¶Àý°¡´ÉÇÑ pressure/suction pump |
|
|
180µµ ¹üÀ§³» ¾î´À °¢µµ¿¡¼³ª controller ¸¦ µ¹·Á¼ º¼ ¼ö ÀÖµµ·Ï ¼³°èµÈ Swivel 180¢â Rotating Controller |
|
|
ÇöÀçÀÇ ½Ã°¢À» Ç¥½ÃÇÏ¿©ÁÖ´Â ½Ã°è°¡ ÀåÂøµÇ¾î ÀÖ¾î ½ÇÁ¦ÀÇ ³¯ÀÚ¿Í ½Ã°¢À¸·Î filter ±³Ã¼ÀÏ°ú °°Àº scheduling °¡´É |
|
|
ÃÖ´ë Áö³ 10ÀϱîÁöÀÇ ¿Âµµ º¯È¸¦ µ¥ÀÌÅÍ¿¡¼ ±×·¡ÇÁ·Î ºÒ·¯³»¾î È®ÀÎ °¡´É |
|
|
ÀåºñÀÇ calibration À» »ç¿ëÀÚ°¡ Á÷Á¢ 10 point ±îÁö ÇÒ ¼ö ÀÖµµ·Ï ¼³°è |
|
|
¾Æ¹«¸® º¹ÀâÇÑ ¿Âµµ program µµ »ý¼º, È®ÀÎ, ¿îÇàÀÌ ¸Å¿ì ºü¸£°í ½±°Ô ÇÒ ¼ö ÀÖµµ·Ï ¼³°è |
|
|
Ethernet, RS232, addressable RS485, remote on/off, USB-A and USB-B plus software support for LabVIEW¢â ¿Í °°Àº ´Ù¾çÇÑ ±â¼úÀÌ ³»ÀåµÇ¾î ¾ðÁ¦ ¾îµð¼µçÁö Àåºñ¸¦ control °¡´É |
|
|
Class III flammability requirements (per DIN 12876-1) ¿¡ ÀûÇÕÇÏ°Ô ¼³°èµÈ ¶Ù¾î³ ¾ÈÀü¼º |
|
|
LidDockTM : Ç׿ÂÁ¶ Ä¿¹ö¸¦ ¼¼¿öµÑ ¼ö ÀÖ´Â Dockr |
|
|
DuraTopTM : ´Ü¿¼º°ú ³»ÈÇмºÀÌ ¿ì¼öÇÑ ¿ÜºÎ ÀçÁú |
|
|
WhisperCool¢ç : ³»ºÎ ¹ß»ý ¿·®¿¡ µû¶ó fan ȸÀü ¼Óµµ¸¦
                         
Á¶ÀýÇϹǷΠ¼ÒÀ½ÀÌ ¸Å¿ì Àû´Ù. |
|
|
Cool CommandTM : ÇÊ¿ä ¿·®¿¡ µû¶ó pulse ¹æ½ÄÀ¸·Î ¿Âµµ¸¦
                               
Á¶ÀýÇÏ¿© È¿À²ÀÌ ¸Å¿ì Ź¿ù |
|
|
|
Controller Type |
|
Advanced Programmable |
|
Maximum Temperature |
|
200¡ÆC |
|
Temperature Stability |
|
¡¾0.005¡ÆC |
|
Swivel 180¢â Rotating Controller |
|
yes |
|
Pump |
|
Variable-speed |
|
Pump Pressure (maximum) psi (bar) |
|
4.3 (0.3) |
|
Pressure Flow Rate (maximum) gpm (l/min) |
|
5.3 (20.1) |
|
Suction Flow Rate (maximum) gpm (l/min) |
|
3.9 (14.7) |
|
Closed-Loop Operation |
|
yes |
|
Closed-Loop Operation |
|
yes |
|
Open-Loop Operation |
|
yes |
|
Fluid Optimization/Specific Heat Tuning |
|
yes |
|
Temperature Calibration Capability |
|
10-point |
|
WhisperCool¢â Environmental Control System |
|
yes |
|
Inert Gas Reservoir Purge |
|
yes |
|
Display Type & Size, SmartTouch Color LCD |
|
4.3 inch |
|
Enhanced Data Display Capability |
|
7 selectable views |
|
Multi-Language Menus or Prompts |
|
11 languages (Korean included) |
|
Displays Temperature Trend |
|
yes |
|
Time/Temperature Programs & Steps |
|
OpenMode |
|
Date & Time with Calendar Start/Stop |
|
yes |
|
Timer |
|
yes |
|
On-Screen Help or Prompts |
|
yes |
|
External Temperature Control Capability (Pt100) |
|
yes |
|
RS232/RS485 Serial Output |
|
yes |
|
Remote On/Off Capability |
|
yes |
|
USB-A and USB-B |
|
yes |
|
Ethernet |
|
yes |
|
DeviceNet¢â/Canbus, Modbus¢ç, Profibus¢ç (optional) |
|
yes |
|
Software Support for LabVIEW¢â Included |
|
yes |
|
Backlit Display |
|
yes |
|
Automatic Loss of Power Reset |
|
Selectable |
|
Safety Class (DIN 12876-1) |
|
III |
|
Over-Temperature Protection |
|
yes |
|
Failsafe Heater Control |
|
yes |
|
High and Low Temperature Limits/Alarms |
|
yes |
|
Low-Liquid-Level Safety |
|
yes |
|
Alarm and Fault Indicators |
|
Message |
|
|