Quintix¢ç Pro Laboratory Balances deliver the performance you need, with added premium features that raise the bar in usability, flexibility and sustainability.



Quintix¢ç Pro Semi Micro Balance
Modern User Interfaces
Status Center
User Management
Continuous Real-Time Level Monitoring
Motorized Levelling
isoCAL : Reliability Guaranteed
Enhanced Traceability
Improved Auto Adaption to Environmental Conditions (AFA)
Easy Cleaning
In-Use Cover
Reliable Backup
Cat. No.
Quintix¢ç Pro Semi-Micro Balances Á¦Ç°¹®ÀÇ
¡Ø °¢ ¸ðµ¨º° °ßÀû¿äûÀº ÆäÀÌÁö ¾Æ·¡ Ordering Information ÂüÁ¶

Quintix¢ç Pro Balance Ä«´Ù·Î±×
Quintix¢ç Pro Balance Datasheet

¹ü¿ëÀûÀ¸·Î »ç¿ëµÇ´Â Sartorius »çÀÇ Entris¢ç Balance ¿¡ Sartorius ÃÖ»óÀÇ ¸ðµ¨ÀÎ Cubis¢ç 2 ÀÇ ÇÁ¸®¹Ì¾ö ±â´ÉÀ» žÀçÇÑ ¸ðµ¨·Î¼­ ÃÖ°íÀÇ °¡¼ººñ¸¦ ÀÚ¶ûÇÏ´Â ¸ðµ¨ÀÓ.
 
Readability (Á¤¹Ðµµ) ¿¡ µû¸¥ Quintix¢ç Pro ¸ðµ¨º° ±¸ºÐ
¸ðµ¨ Analytical Miligram Precision
Á¤¹Ðµµ [mg] 0.1 1 10 | 100


Effortless Operation
Quintix¢ç Pro Àú¿ïÀº ´©±¸µçÁö ¾ÆÁÖ ºü¸£°í ½±°Ô »ç¿ëÇÒ ¼ö ÀÖµµ·Ï ¼³°èµÇ¾î ÀÖ½À´Ï´Ù. Startup Assistant °¡ ³»ÀåµÇ¾î ÀÖ¾î Balance ¸¦ ¸Å¿ì ½±°í ºü¸£°Ô ¼³Ä¡ÇÒ ¼ö ÀÖ½À´Ï´Ù.
±×¸®°í Interactive Manual ÀÌ ³»ÀåµÇ¾î ÀÖ¾î »ç¿ë»óÀÇ ºÒÆíÇÔÀÌ ÀÖÀ» °æ¿ì ¹®Á¦Á¡À» ¼Õ½±°Ô ÇØ°áÇÒ ¼ö ÀÖ½À´Ï´Ù.
Status Center
Quintix¢ç Pro ÀÇ ¸ÞÀÎ ÆäÀÌÁöÀÎ Status Center È­¸é¿¡´Â Àú¿ïÀÇ ¼öÆò»óÅÂ, Calibration »óÅÂ¿Í °°Àº Balance ÀÇ ¸ðµç ÁÖ¿ä ³»¿ëµéÀÌ display µÇ¾îÀÖ¾î ÇѹøÀÇ Å¬¸¯À¸·Î Balance °ü¸®¸¦ ¸Å¿ì Æí¸®ÇÏ°Ô ÇÒ ¼ö ÀÖ½À´Ï´Ù.
User Management
ÃÖ½ÅÀÇ User Managemenat ÇÁ·Î±×·¥ÀÌ ÀåÂøµÇ¾î °¢ »ç¿ëÀÚÀÇ Àú¿ï »ç¿ë ¹üÀ§¸¦ °¢°¢ ÁöÁ¤ÇÒ ¼ö ÀÖÀ¸¸ç ±ÇÇÑÀ» ºÎ¿©¹ÞÁö ¾ÊÀº »ç¿ëÀÚ´Â Á¢±ÙÀ» Â÷´ÜÇÒ ¼ö ÀÖ´Â ¸Þ´ºµµ ¼³Á¤ÇÒ ¼ö ÀÖ¾î Balance ÀÇ µ¥ÀÌÅ͸¦ ¿Ïº®ÇÏ°Ô º¸È£ÇÒ ¼ö ÀÖ½À´Ï´Ù.
Continuous Real-Time Level Monitoring
Quintix¢ç Pro ¿¡´Â LevelControl ±â´ÉÀÌ ÀÖ½À´Ï´Ù. Àú¿ïÀÌ ¼öÆòÀÎ »óÅ¿¡ ÀÖ´ÂÁö ¿¬¼ÓÀ¸·Î ½Ç½Ã°£ È®ÀÎÇÏ¿© ¼öÆòÀÌ Á¶±ÝÀÌ¶óµµ ¾î±ß³ª°Ô µÇ¸é °æ°í¸¦ ¾Ë¸®°í ÃøÁ¤ µ¥ÀÌÅÍ°¡ PC ¶Ç´Â ÇÁ¸°Æ®·Ñ Àü¼ÛµÇ´Â °ÍÀ» Â÷´ÜÇÏ°Ô µË´Ï´Ù. ±×¸®°í Quintix¢ç Pro ´Â »ç¿ëÀÚ°¡ ¼öÆòÀ» ¼Õ½±°Ô ¸ÂÃâ ¼ö ÀÖµµ·Ï ½Ç½Ã°£À¸·Î ¾È³»ÇÏ¿© ÁÝ´Ï´Ù.
Motorized Leveling
Àú¿ïÀÇ ¼öÆòÀÌ Æ²·ÁÁ³À» ¶§¿¡ Automatic Leveling ÆäÀÌÁö¿¡¼­ button À» ¼±Åø¸ Çϸé Quintix¢ç Pro ´Â Àüµ¿À¸·Î ÀÛµ¿ÇÏ´Â 4°³ÀÇ ´Ù¸®¸¦ ÀÌ¿ëÇÏ¿© ÀÚµ¿À¸·Î ¼öÆòÀ» Á¶ÀýÇÏ°Ô µË´Ï´Ù. (optional)
isoCAL : Reliability Guaranteed
ÁÖº¯ÀÇ ¿Âµµ º¯È­´Â ÃøÁ¤ °á°ú¸¦ ¿Ö°î½Ãų ¼ö ÀÖ½À´Ï´Ù. Quintix¢ç Pro ¿¡ ³»ÀåµÈ temperature- and time-controlled calibration and adjustment ±â´ÉÀÎ isoCAL (internal calibration and adjustment) ¿¡ ÀÇÇØ ÀÌ·¯ÇÑ °á°ú ¿Ö°î¿¡ ´ëÇÑ ¿°·Á¸¦ ¾ø¾ÖÁÝ´Ï´Ù. Àú¿ï¿¡¼­ isoCAL ÀÛµ¿À» À§ÇÑ time interval ¸¸ ¼³Á¤Çϸé Ç×»ó »ç¿ëÀÚÀÇ Ç¥ÁØ Á¶°Ç´ë·Î ÃøÁ¤ÀÌ ÀÌ·ç¾îÁý´Ï´Ù.
Enhanced Traceability
Quintix¢ç Pro ³»ºÎ¿¡ ÀåÂøµÈ Device-Log ±â´É¿¡ ÀÇÇØ calibration, leveling procedure, balance setting, ÃøÁ¤°ª ¼³Á¤ µî ¸ðµç µ¥ÀÌÅ͵éÀÌ ÀÚµ¿ ÀúÀå µÇ¾îÁö°í ÀÌ Log File ÀÇ µ¥ÀÌÅÍ´Â ³¯ÀÚ¿Í ½Ã°£º°·Î ¾ðÁ¦µçÁö È®ÀÎÀÌ °¡´ÉÇÕ´Ï´Ù.
Secure Weighing Data Continuously
Quintix¢ç Pro ´Â ÃøÁ¤µÈ µ¥ÀÌÅ͸¦ ¿©·¯°³ÀÇ º¸¾Èµî±Þ (high, standard, low µî) À¸·Î ±¸ºÐÇÏ¿© ¼³Á¤ÇÒ ¼ö ÀÖ½À´Ï´Ù. µ¥ÀÌÅÍ Àü¼Û½Ã ¿ä±¸µÇ´Â º¸¾È level ¿¡ ¸Â´Â µ¥ÀÌÅ͸¸ monitoring Àü¼ÛÇÏ°Ô ÇÕ´Ï´Ù.
Improved Auto Adaption to Environmental Condtions (AFA)
Àú¿ï ÁÖº¯ÀÇ È¯°æÀÌ ºÒ¾ÈÁ¤ÇÏ¿©µµ Quintix¢ç Pro ´Â ÇѹøÀÇ Å¬¸¯À¸·Î ƯÁ¤ ȯ°æ Á¶°Ç¿¡ ½±°Ô ÀûÀÀÀ» ÇÒ ¼ö ÀÖµµ·Ï ¼³°èµÇ¾î ÀÖ½À´Ï´Ù.
Extended Protection with In-Use-Cover
Quintix¢ç Pro ´Â in-use-cover ¸¦ ÀÌ¿ëÇϸé ÃøÁ¤Áß¿¡ Balance °¡ contamination µÇ´Â °ÍÀ» ¹æÁöÇÒ ¼ö ÀÖ½À´Ï´Ù. Àú¿ï Àüü¸¦ °¨½Ò ¼ö ÀÖ´Â Ä¿¹ö, weighing pan ¶Ç´Â draft shield base plate ¸¦ º¸È£ÇÏ´Â Ä¿¹öµµ ÀÖ½À´Ï´Ù.
Extended Protection with In-Use-Cover
in-use cover ¸¦ »ç¿ëÇϸé balance °¡ contamination µÇ´Â °ÍÀ» ¹æÁöÇÒ ¼ö ÀÖ½À´Ï´Ù. ¶ÇÇÑ µ¶¼º ¹°ÁúÀ» Ãë±ÞÇÏ´Â Àå¼Ò¿¡¼­ Àú¿ïÀ» »ç¿ëÇÒ °æ¿ì¿¡´Â protection cover ¸¦ Ãß°¡·Î »ç¿ëÇϸé weighing pan °ú draft shield base plate ¸¦ º¸È£ÇÏ´Â µ¥ Å« È¿°ú°¡ ÀÖ½À´Ï´Ù.
Easy Cleaning
Quintix¢ç Pro ÀÇ ÀçÁúÀº ³»±¸¼º°ú ³»È­ÇмºÀÌ Å¹¿ùÇÑ PBT (polybutylene terephthalate), stainless steel, glass ÀçÁú·Î ÀÌ·ç¾îÁ® ÀÖ¾î È­Çй°Áú¿¡ ÀÇÇØ º¯»ö, ºÎ½Ä µîÀÌ ÀϾÁö¾Ê°í û¼Òµµ ¸Å¿ì ½±°í °íÀå¾øÀÌ ¿À·¡µ¿¾È »ç¿ëÀÌ °¡´ÉÇÕ´Ï´Ù.
Documentation and Data Transfer
Quintix¢ç Pro ´Â USB Type-C interfaces, RS232 9-pin interface ±×¸®°í ethernet interface ¸¦ ÀÌ¿ëÇÏ¿© ¿ÜºÎÀåÄ¡¿Í Á÷Á¢ ¿¬°áÇϰųª USB stick À» ÀÌ¿ëÇÏ¿© ÃøÁ¤ µ¥ÀÌÅÍ, clabiration data µîÀ» Àü´ÞÇÒ ¼ö ÀÖ½À´Ï´Ù.
Data Transfer : Direct and Correct
Quintix¢ç Pro ´Â USB Type-C interface port ¿Í Plug & Play technology ¸¦ ÀÌ¿ëÇÏ¿© º°µµÀÇ ¼ÒÇÁÆ®¿þ¾î ¶Ç´Â ÀåÄ¡¾øÀÌ Àú¿ï ÃøÁ¤ °á°ú¸¦ PC ¶Ç´Â lab print ·Î Á÷Á¢ Àü¼ÛÀÌ °¡´ÉÇÕ´Ï´Ù.
Data Documentation : Fast and Easy
Quintix¢ç Pro ´Â ¿¬°áµÈ ½ÇÇè½Ç ÇÁ¸°Æ®·Î ÃøÁ¤ °á°ú¸¦ Àü¼ÛÇÏ¿© data document ¸¦ ¹Ù·Î ÇÁ¸°Æ®ÇÒ ¼ö ÀÖ½À´Ï´Ù. Ç¥Áر԰ÝÀÇ paper ±×¸®°í roll ÇüÅÂÀÇ paper µî Á¦ÇѾøÀÌ document ¸¦ ÇÁ¸°Æ®ÇÒ ¼ö ÀÖ½À´Ï´Ù.
Sample Identification : Even More Reliable and Precise with Quintix¢ç Pro :
»ùÇà ½Äº°ÀÌ ¸Å¿ì Áß¿äÇÑ °æ¿ì¿¡´Â Quintix¢ç Pro ¿¡ ³»ÀåµÈ sample indentification ±â´ÉÀ» »ç¿ëÇÏ¸é »ùÇà ½Äº°À» ¸Å¿ì Æí¸®ÇÏ°Ô ÇÒ ¼ö ÀÖ½À´Ï´Ù. ¿¹¸¦ µé¾î ÃøÁ¤ °á°ú¸¦ ÇÁ¸°Æ®ÇÒ ¶§ »ùÇÃÀÇ ID ¸¦ ÇÊ¿ä¿¡ µû¶ó ´Ù¾çÇÑ ÇüÅ·ΠºÎ¿©ÇÒ ¼ö ÀÖ½À´Ï´Ù.
Flexible Maintenance and Reliable Backup :
Quintix¢ç Pro ÀÇ À¯Áöº¸¼ö Áֱ⸦ ¼³Á¤Çϸé Ãʱ⿡ ¼³Á¤µÈ SOP ¸¦ ±×´ë·Î À¯ÁöÇÏ¿© »ç¿ëÇÒ ¼ö ÀÖ½À´Ï´Ù. ¼³Á¤µÈ ¸ðµç balance Á¶°ÇµéÀ» backup ¹Þ¾Æ USB ¿Í °°Àº ¿ÜºÎ ÀåÄ¡¿¡ ÀúÀåÇϽʽÿä. ÀúÀåµÈ balance ¼³Á¤ Á¶°ÇµéÀº ¾ðÁ¦µçÁö ¿ø balance ¿¡ À缳ġ °¡´ÉÇÕ´Ï´Ù.
FAT Test Report :
°í°´ÀÌ ÁÖ¹®ÇÑ Quintix¢ç Pro °¡ ³³Ç°µÉ ¶§¿¡´Â µ¶ÀÏ Sartorius °¡ ½Ç½ÃÇÑ ÇØ´ç Quintix¢ç Pro ÀÇ Ç°Áú Å×½ºÆ® º¸°í¼­ÀÎ FAT (factory acceptance test) Report °¡ ÇÔ²² Á¦°øµË´Ï´Ù.
ÃÖ½ÅÀÇ user interface ¸¦ ÀåÂøÇÑ 7ÀÎÄ¡ °íÇØ»óµµ full-touch graphic display
cleanroom grade A and grade B Á¶°Ç¿¡¼­µµ »ç¿ëÀÌ °¡´ÉÇϸé ƯÈ÷ Áø°ø, ¾Æ¸£°ï, Áú¼Ò ȯ°æ°ú °°Àº Ư¼ö ȯ°æ¿¡¼­µµ »ç¿ëÀÌ °¡´É
15°³ÀÇ ¾ð¾î Áö¿ø
»ç¿ë ÇÏÁö ¾ÊÀ» ½Ã display ÀÇ ¹à±â ÀÚµ¿À¸·Î Èå·ÁÁö´Â ±â´É
¼³Á¤µÈ ½Ã°£¿¡ ÀÚµ¿À¸·Î Àü¿øÀÌ ÄÑÁö°í »ç¿ë°¡´ÉÇÑ »óÅ·ΠÀüȯ
Integrated Application Programs for Efficient Working Routines :
Quintix¢ç Pro ¿¡´Â »ç¿ëÀÚ°¡ ¸¹ÀÌ »ç¿ëÇÏ´Â application ¿Ü¿¡µµ Quintix¢ç Pro ÀÚü¿¡ ³»ÀåµÈ program ÀÌ ¸¹ÀÌ ÀúÀåµÇ¾î ÀÖ¾î ¾î¶² application ¿¡¼­µµ ÀûÀýÈ÷ »ç¿ëÀÌ °¡´ÉÇÑ Universal Balance.
- Weighing | Dosing - Mass Unit Conversion
- Counting - Percentage Weighing
- Calculation - Mixing
- Components - Statistics
- Density Determination - Checkweighing
- Animal Weighing - Peak Hold
- Pipette Smart Check - Differential Weighing
- Underfloor Weighing






Watch the Quintix¢ç Pro in Action



Sartorius Services for Quintix¢ç Pro Laboratory Balances

Installation and Commissioning : Reliable Results Right from the Start
Your Advantage :
ÃʱâºÎÅÍ ÃÖÀûÀÇ »óÅ·Π¹«°Ô ÃøÁ¤ ¼º´ÉÀ» °¡Áú ¼ö ÀÖµµ·Ï ¼³Ä¡ ÇÏ¿©µå¸³´Ï´Ù.
»ç¿ëÀÚÀÇ ½ÇÇè½Ç ȯ°æ¿¡ Sartorius Balance ¸¦ ÃÖÀûÀÇ »óÅ·ΠÅëÇÕÇÏ¿© µå¸³´Ï´Ù.
ÃÖÀûÀÇ ½Ã½ºÅÛ ¼º´É°ú °á°ú¸¦ Á¦°øÇÕ´Ï´Ù.
Àü¹®ÀûÀ¸·Î ¼÷·ÃµÈ ±â¼úÁøµéÀÌ ¼³Ä¡¸¦ ÁøÇàÇÕ´Ï´Ù.
 
Equipment Qualification (IQ | OQ) : Compliance with GMP Requirements
Your Advantage :
GMP, GLP ±ÔÁ¤¿¡ ÃÖ°í·Î ÀûÇÕÇÏ°Ô ÁøÇàÇÕ´Ï´Ù.
Audit Security
Sartorius ÀÇ risk ȸÇÇ °³³äÀ» ±â¹ÝÀ¸·Î ¸ðµç Áß¿ä ÀåºñµéÀ» ü°èÈ­ ÇÏ¿´½À´Ï´Ù.
ÇÊ¿äÇÑ ¸ðµç ±ÔÁ¤°ú ±â¼úÀû Áö½ÄÀ» ¹ÙÅÁÀ¸·Î IQ | OQ ¸¦ ÁøÇàÇÕ´Ï´Ù.
 
Preventive Maintenance and Service Contracts : Long-Term Process Safety and Reliable Results
Your Advantage :
º¸À¯ÇÏ°í ÀÖ´Â Àú¿ïÀ» Ç×»ó ÃÖÀûÀÇ »óÅ·Π»ç¿ëÇÒ ¼ö ÀÖ½À´Ï´Ù.
Balance ¸¦ ¸Å¿ì ¿À·§µ¿¾È »ç¿ëÇÒ ¼ö ÀÖ½À´Ï´Ù.
Ç×»ó GMP, GLP ¿Í °°Àº ±ÔÁ¤¿¡ ÀûÇÕÇÑ Á¶°Ç¿¡¼­ Balance ¸¦ »ç¿ëÇÒ ¼ö ÀÖ½À´Ï´Ù.
»ç¿ëÀÚÀÇ ¿©°Ç¿¡ ¸ÂÃß¾î ¼­ºñ½º °è¾àÀ» ÇÒ ¼ö ÀÖÀ¸¹Ç·Î Àüü ºñ¿ëÀ» ÀûÀýÈ÷ Á¶ÀýÇÒ ¼ö ÀÖ½À´Ï´Ù.
 
Calibration Services : Traceability of Weighing Results, Regulatory Compliance
Your Advantage :
´ëºÎºÐÀÇ ±¹°¡¿¡¼­ ÀÎÁ¤ÇÏ´Â, ½ÇÇè½Ç Ç°Áú °ü¸® ½Ã½ºÅÛ ÀÎÁõ¼­ÀÎ ISO/IEC 17025 calibration certificate
±¹°¡ Ç¥ÁØ¿¡ ÀûÇÕÇÑ traceability ±â´É º¸Àå
¹Ì±¹°ú À¯·´ ¾àÀü ÀÎ USP<41> & Ph.Eur.2.1.7 Á¶°Ç¿¡ ÀûÇÕÇÑ minimum weight certificate
Àú¿ï ¹× ÃøÁ¤±â¿¡ ´ëÇÑ ±¹Á¦ ±âÁØÀÎ OIML (±¹Á¦ °è·®À§¿øȸ, International Organization of Legal Metrology) ÀÇ ±Ô°Ý R76 ¿¡ µû¶ó ½ÂÀÎµÈ balance ¿¡ ´ëÇÑ certificate



Quintix¢ç Pro - Technical Specifications & Ordering Information


Quintix Pro Balances :: Motorized Level Feet
Picture Model Readability Capacity Remarks
QTX324IMU-1SKR 0.1 mg 320g For 4 digit Balance / ÇѱÛÁö¿ø ÅÍÄ¡½ºÅ©¸°
/ isoCAL ³»ºÎº¸Á¤ / ÀÚµ¿ ¼öÆòÁ¶Àý °¡´É
QTX224IMU-1SKR 0.1 mg 220g
QTX124IMU-1SKR 0.1 mg 120g
QTX1503IMU-1SKR 0.001 g 1,500g For 3 digit Balance / ÇѱÛÁö¿ø ÅÍÄ¡½ºÅ©¸°
/ isoCAL ³»ºÎº¸Á¤ / ÀÚµ¿ ¼öÆòÁ¶Àý °¡´É
QTX1203IMU-1SKR 0.001 g 1,200g
QTX623IMU-1SKR 0.001 g 620g
QTX423IMU-1SKR 0.001 g 420g
QTX323IMU-1SKR 0.001 g 320g
QTX6202IMO-1SKR 0.01 g 6,200g For 2 digit Balance / ÇѱÛÁö¿ø ÅÍÄ¡½ºÅ©¸°
/ isoCAL ³»ºÎº¸Á¤ / ÀÚµ¿ ¼öÆòÁ¶Àý °¡´É
QTX4202IMO-1SKR 0.01 g 4,200g
QTX3202IMO-1SKR 0.01 g 3,200g
QTX2202IMO-1SKR 0.01 g 2,200g
QTX1202IMO-1SKR 0.01 g 1,200g
QTX12201IMO-1SKR 0.1 g 12,200g For 1 digit / ÇѱÛÁö¿ø ÅÍÄ¡½ºÅ©¸°
/ isoCAL ³»ºÎº¸Á¤ / ÀÚµ¿ ¼öÆòÁ¶Àý °¡´É
QTX10201IMO-1SKR 0.1 g 10,200g
QTX8201IMO-1SKR 0.1 g 8,200g
QTX6201IMO-1SKR 0.1 g 6,200g
QTX3201IMO-1SKR 0.1 g 3,200g


Quintix Pro Balances :: Realtime Level Supporting
Picture Model Readability Capacity Remarks
QTX324IRU-1SKR 0.1 mg 320g For 4 digit Balance / ÇѱÛÁö¿ø ÅÍÄ¡½ºÅ©¸°
/ isoCAL ³»ºÎº¸Á¤ / ¼öÆòÁ¶Àý °¡À̵å
QTX224IRU-1SKR 0.1 mg 220g
QTX124IRU-1SKR 0.1 mg 120g
QTX1503IRU-1SKR 0.001 g 1,500g For 3 digit Balance / ÇѱÛÁö¿ø ÅÍÄ¡½ºÅ©¸°
/ isoCAL ³»ºÎº¸Á¤ / ÀÚµ¿ ¼öÆòÁ¶Àý °¡´É
QTX1503IRU-1SKR 0.001 g 1,200g
QTX623IRU-1SKR 0.001 g 620g
QTX423IRU-1SKR 0.001 g 420g
QTX323IRU-1SKR 0.001 g 320g
QTX6202IRO-1SKR 0.01 g 6,200g For 2 digit Balance / ÇѱÛÁö¿ø ÅÍÄ¡½ºÅ©¸°
/ isoCAL ³»ºÎº¸Á¤ / ÀÚµ¿ ¼öÆòÁ¶Àý °¡´É
QTX4202IRO-1SKR 0.01 g 4,200g
QTX3202IRO-1SKR 0.01 g 3,200g
QTX2202IRO-1SKR 0.01 g 2,200g
QTX1202IRO-1SKR 0.01 g 1,200g
QTX12201IRO-1SKR 0.1 g 12,200g For 1 digit / ÇѱÛÁö¿ø ÅÍÄ¡½ºÅ©¸°
/ isoCAL ³»ºÎº¸Á¤ / ÀÚµ¿ ¼öÆòÁ¶Àý °¡´É
QTX10201IRO-1SKR 0.1 g 10,200g
QTX8201IRO-1SKR 0.1 g 8,200g
QTX6201IRO-1SKR 0.1 g 6,200g
QTX3201IRO-1SKR 0.1 g 3,200g