Background
Translucent nanoemulsion Àº Á÷°æ 100nm ÀÌÇÏ·Î ¸Å¿ì ÀÛ°í ÀÔµµºÐÆ÷°¡
¸Å¿ì ±ÕÀÏÇÑ Æ¯¼ºÀ» °¡Áø nanoemulsion À» ¸»ÇÑ´Ù.
ÀÌ emulsion Àº Åõ¸íÇÏ°í Á¡µµ°¡ ¸Å¿ì ³·À¸¸ç Àå±â°£ º¸°üÇÏ¿©µµ ¾ÈÁ¤¼ºÀÌ À¯ÁöµÇ°í ¶ÇÇÑ È°¼º¹°ÁúÀ» °í³óµµ·Î ¿î¹ÝÇÒ ¼ö ÀÖ´Â µî
¸Å¿ì ±àÁ¤ÀûÀΠƯ¼ºÀ» ¸¹ÀÌ °¡Áö°í ÀÖ´Ù.
|
|
Examples of Produced Translucent Nanoemulsions
translucent nanoemulsion Á¦Á¶½Ã¿¡ ÀÏ¹Ý probe ¿Í High-intensity Probe ÀÇ Ã³¸®·®¿¡ ´ëÇÑ Â÷À̸¦ È®ÀÎÇϱâ À§ÇÑ Å×½ºÆ®¸¦ ´ÙÀ½°ú °°ÀÌ
ÁøÇàÇÏ¿´´Ù.
|
ÀÏ¹Ý probe |
High-intensity Probe |
  sample |
10% soybean oil + 6% À¯ÈÁ¦ |
10% soybean oil + 6% À¯ÈÁ¦ |
  ¸ñÇ¥ ÀÔµµÅ©±â |
75 ~ 80 nm |
75 ~ 80 nm |
  Pre-mixing |
500rpm for 2min. by magnetic stirrer |
500rpm for 2min. by magnetic stirrer |
  probe diameter |
15mm |
35mm |
  amplitude |
90 § |
90 § |
  power |
1200 watt |
1200 watt |
Test by Conventional Probe
Á÷°æ 15mm ÀÇ ÀÏ¹Ý probe ¸¦ ÀÌ¿ëÇÏ¿© sample À» ¼øȯ½Ä (recirculation) ¹æ¹ýÀ¸·Î À¯Èó¸®ÇÏ¿´À¸¸ç
sample 󸮼ӵµ´Â 4, 5, 6.7, 10, ±×¸®°í 20 ml/min. ·Î flow rate ¸¦ ´Þ¸®ÇÏ¿© ½ÇÇèÇÏ¿´´Ù.
4ml/min. ÀÇ flow rate ·Î ÇÏ¿´À» °æ¿ì ÀÔµµ´Â ¾à 30nm, 6.7ml/min. ÀÇ flow rate ¿¡¼´Â ¾à 50nm,
±×¸®°í 10ml/min. ÀÇ flow rate ¿¡¼´Â ¸ñÇ¥ ÀÔµµÀÎ 80nm ÀÇ droplet size ¸¦ °¡Áø translucent emulsion À» ±¸ÇÒ ¼ö ÀÖ¾ú´Ù.
Test by High-intensity Probe
35mm Á÷°æÀ» °¡Áø °íÃâ·Â probe ¸¦ ÀÌ¿ëÇÏ¿© nanoemulsion sample À» À¯È ó¸®ÇÏ¿´À¸¸ç
sample 󸮼ӵµ´Â 60, 75, 100, ±×¸®°í 150ml/min. ·Î °¢±â ´Ù¸¥ flow rate ·Î ½ÇÇèÇÏ¿´´Ù.
100 ml/min. ÀÇ flow rate ¿¡¼ ¸ñÇ¥ ÀÔµµÀÎ ¾à 70nm ÀÇ droplet size ¸¦ °¡Áø nanoemulsion À» ±¸ÇÒ ¼ö ÀÖ¾ú´Ù.
¡Ø |
ÀÌ Å×½ºÆ®¸¦ ÅëÇØ ¿ì¸®´Â High-intensity Probe ´Â ÀÏ¹Ý probe ¿Í µ¿ÀÏÇÑ °á°ú¸¦ ³ªÅ¸³»¸é¼µµ
ÀÏ¹Ý probe º¸´Ù 10¹è ´õ ¸¹Àº ¾çÀÇ sample À» ó¸®ÇÒ ¼ö ÀÖ´Ù´Â °ÍÀ» ÀǹÌÇÑ´Ù. |
|
|
|
|