References |
|
ISO 10694 : |
Soil quality - Determination of organic and total carbon after dry combustion (Elemental analysis) |
ISO 13878 : |
Soil quality - Determination of total nitrogen content by dry combustion (Elemental analysis) |
EN13654-2 : |
Soil improvers and growing media - Determination of nitrogen - Part 2: Dumas method |
Gazzetta ufficiale Official Italian Method 248.1999 |
Tested with VELP Scientifica CN 802 Carbon Nitrogen Analyzer (Code F30800090) |
|
Introduction
ź¼Ò:Áú¼Ò ºñÀ² (carbon-to-nitrogen ratio, C:N ratio) Àº ÀÜ·ù¹° ºÐÇØ (residue decomposition) ¿Í Åä¾çÀÇ Áú¼Ò ¼øȯ (nitrogen cycling in soils) ¿¡ Á÷Á¢ÀûÀÎ ¿µÇâÀ» ¹ÌÄ¡´Â º¯¼ö·Î½á ¸Å¿ì Áß¿äÇÏ´Ù.
½Ä¹°°ú ¹Ì»ý¹°ÀÇ Áú¼Ò Á¦ÇÑ¿¡ ´ëÇÑ ÁöÇ¥·Î »ç¿ëµÇ±â ¶§¹®ÀÌ´Ù.
ÀϹÝÀûÀ¸·Î ÀÌ ºñÀ²ÀÌ ³ôÀ»¼ö·Ï ¹°ÁúÀÌ ºÐÇصǴµ¥ ½Ã°£ÀÌ ¿À·¡ °É¸®±â ¶§¹®ÀÌ´Ù.
¹Ý´ë·Î ÀÌ ºñÀ²ÀÌ ³·À»¼ö·Ï ¹°Áú, ƯÈ÷ ½Ä¹°ÀÌ ´õ »¡¸® ºÐÇص˴ϴÙ. ÀÌ·¯ÇÑ ¸ÞÄ¿´ÏÁòÀº ´ÙÀ½¿¡ ÀÚ¶ó´Â ½Ä¹°ÀÌ »ç¿ëÇÒ ¼ö ÀÖ´Â Åä¾ç ³» Áú¼Ò·®°ú Á÷Á¢ÀûÀÎ °ü°è°¡ ÀÖ´Ù.
VELP»ç ¿ø¼Ò¼ººÐºÐ¼®±â CN 802 ¸¦ ÀÌ¿ëÇÏ¿© Åä¾ç »ùÇÃÀ» ºÐ¼®ÇÏ°í ¾òÀº °á°ú¸¦ WEPAL (Wageningen Evaluating Programs for Analytical Laboratories) ¿¡¼ Çã¿ëÇÏ´Â
Åë°è ¹üÀ§¿Í ºñ±³ÇÏ¿© ÇØ´ç ÀåºñÀÇ ÃøÁ¤ Á¤È®µµ¸¦ ºÐ¼®ÇÏ¿´´Ù.
À̸¦ ÅëÇØ ÇØ´ç ÀåºñÀÇ ¼º´ÉÀº WEPAL ¿¡¼ ÁÖ°üÇÏ´Â ¼÷·ÃµÈ Å×½ºÆ® ÇÁ·Î±×·¥ (the Proficiency Testing program) ¿¡ ÀÇÇØ Æò°¡µÇ¾ú´Ù.
Carbon and Nitrogen Determination in Soils
¨ç |
CN802 C. N ¿ø¼ÒºÐ¼®±â´Â ¸ÕÀú ½Ã·á¸¦ combustion (CF) ÇÏ¿© ½Ã·á¸¦ ¿¬¼ÒÇÑ´Ù.½ÃÅ°´Ù. |
¨è |
±× ´ÙÀ½ ´Ü°èÀÎ physical trap ÀÎ WT1-DriStep¢â ´Ü°è¿¡¼ water ¸¦ Á¦°ÅÇÑ´Ù |
¨é |
±×¸®°í reduction furnace (RF) ´Ü°è¿¡¼ Áú¼Ò»êȹ° (NOx) ¸¦ Á¦°ÅÇÑ´Ù. |
¨ê |
´Ù½Ã µÎ¹ø° physical trap ÀÎ WT2-DriStep¢â ´Ü°è¿¡¼ water ¸¦ ´Ù½ÃÇѹø ´õ Á¦°ÅÇÑ´Ù. |
¨ë |
NDIR (Non-Dispersive Infrared NDIR Detector) ´Ü°è¿¡¼ CO©ü ³óµµ¸¦ ÃøÁ¤ÇÏ°í ÀÌ ³óµµ ¼öÄ¡´Â Carbon ¾çÀ¸·Î °è»êµÇ¾îÁø´Ù. |
¨ì |
±×¸®°í ÀÌ ÀåÄ¡¿¡ ÇÔ²² ÀÖ´Â auto-regenerative CO©ü absorbers °¡ CO2 ¸¦ ¿ÏÀü Èí¼öÇÑ´Ù. |
¨í |
ÃÖÁ¾ ´Ü°è¿¡¼ LoGas¢â TCD (Thermal Conductivity Detector) °¡ Áú¼Ò ³óµµ¸¦ ÃøÁ¤ÇÑ´Ù. |
CN 802 Preliminary Operations (daily)
¾Æ·¡ ÃøÁ¤ Á¶°Ç°ú °°ÀÌ Åä¾ç ³» ź¼Ò ¹× Áú¼ÒÀÇ ÇÔ·®À» ÃøÁ¤ÇÏ¿´´Ù |
¡Ü |
Temperature Combustion reactor (Code A00000158) : 1030 ¡ÆC |
¡Ü |
Temperature Reduction reactor (Code A00000226) : 650 ¡ÆC |
¡Ü |
Flow rate MFC1 He : 190 ml/min |
¡Ü |
Flow rate MFC2 He : 220 ml/min |
¡Ü |
calibration ¿ë Ç¥ÁØ »ùÇà : 2 EDTA standard (Code A00000149) |
¡Ü |
CHECK UP »ùÇÃ : 3 to 5 empty tin foils (Code A00000153) |
Ç¥ÁØ »ùÇÃÀ» ÀÌ¿ëÇÏ¿© Calibration Curve ¸¦ »ý¼ºÇÏ¿© ÃøÁ¤ ¹× ºÐ¼®¿¡ »ç¿ëÇÏ¿´´Ù. |
Sample Preparation
Å×½ºÆ®¿¡ »ç¿ëµÇ´Â WEPAL ÀÇ reference soil and sediment »ùÇÃÀº ´ÙÀ½°ú °°´Ù.
Reference Samples : |
Expected Values on Dry Matter : |
|
Wepal ISE 2018-4 Sediment sample 860 |
C % = 4.524 ¡¾ 0.207 N % = 0.1628 ¡¾ 0.0132 |
|
Wepal ISE 2018-4 Clay sample 879 |
C % = 2.911 ¡¾ 0.072 N % = 0.1688 ¡¾ 0.0126 |
|
Wepal ISE 2018-4 Sandy soil sample 919 |
C % = 2.586 ¡¾ 0.207 N % = 0.1487 ¡¾ 0.0142 |
|
Wepal ISE 2018-4 Sandy soil sample 993 |
C % = 2.624 ¡¾ 0.119 N % = 0.2361 ¡¾ 0.0117 |
|
Åä¾ç »ùÇÃÀº ºÐ¼® Àü¿¡ 105¡ÆC¿¡¼ °ÇÁ¶µÇ¾úÀ¸¸ç spatula ·Î 300mgÀÇ »ùÇÃÀ» È£ÀÏ¿¡ ³Ö´Â´Ù.
±×¸®°í È£ÀÏÀ» ´Ý¾Æ ĸ½¶Ã³·³ ¸¸µç ´ÙÀ½ Àåºñ »óºÎ¿¡ À§Ä¡ÇÑ autosampler ¿¡ ³Ö´Â´Ù.
Analysis Procedure
´ÙÀ½°ú °°Àº Á¶°ÇÀ¸·Î TC, TN, TOC ¸¦ ÃøÁ¤ÇÏ¿´´Ù.
- Protein factor: none
- O2 flow rate: 300 ml/min
- O2 factor: 1.6 ml/mg
- ºÐ¼®½Ã°£ : from 3 minutes for one run
Typical C and N Results on Soil samples
ź¼Ò ÃøÁ¤ °á°ú´Â 0 - 20 mg C ¹üÀ§¿¡¼ standard CaCO3(C% = 12)¸¦ »ç¿ëÇÏ¿© »ý¼ºÇÑ Calibration Curve ¸¦ ±âÁØÀ¸·Î ºÐ¼®ÇÏ¿´´Ù.
Áú¼Ò ÃøÁ¤ °á°ú´Â 0 - 1.5 mg N ¹üÀ§¿¡¼ ¾Æ½ºÆĸ£Æ®»ê (aspartic acid, C4H7NO4) ¸¦ »ç¿ëÇÏ¿© »ý¼ºÇÑ Calibration Curve ¸¦ ±âÁØÀ¸·Î ºÐ¼®ÇÏ¿´´Ù.
ÀÌ·¯ÇÑ ÃøÁ¤ °á°ú´Â certificate of analysis ¿¡¼ Çã¿ëÇÏ´Â ¿ÀÂ÷ ¹üÀ§¿¡ Æ÷ÇԵǾú´Ù.
4°³ÀÇ WEPAL Á¦°ø »ùÇà ¸ðµÎ CN 802ÀÇ ¹Ýº¹¼ºÀ» Æò°¡Çϱâ À§ÇØ 10ȸ¾¿ ¹Ýº¹ ÃøÁ¤ÇÏ¿´À¸¸ç ±× °á°ú´Â ¾Æ·¡Ç¥¿¡ ³ªÅ¸³»¾ú´Ù.
¼ÒÇÁÆ®¿þ¾î CNSoft ´Â ratio C:N ¸¦ ÀÚµ¿À¸·Î °è»êÇϸç ÀÌ ¶ÇÇÑ Ç¥¿¡ ±â·ÏÇÏ¿´´Ù.
Conclusion
VELP Scientifica CN 802 ź¼Ò Áú¼Ò ºÐ¼®±â´Â Åä¾ç ½Ã·áÀÇ Åº¼Ò¿Í Áú¼Ò ¹× C:N ºñÀ² ÃøÁ¤À» À§ÇÑ ÀÌ»óÀûÀÎ ¼Ö·ç¼ÇÀÌ´Ù.
ºÐ¼®±â´Â ¼ÒÇÁÆ®¿þ¾î CNSoft ¿¡ ÀÇÇÑ ÀÚµ¿ °è»êÀ¸·Î ½±°í ºü¸¥ ¹æ¹ýÀ¸·Î ½Å·ÚÇÒ ¼ö ÀÖ´Â °á°ú¸¦ º¸ÀåÇÑ´Ù.
À§ Ç¥¿¡¼ ³ªÅ¸³½ ¹Ù¿Í °°ÀÌ ºÐ¼® °á°ú´Â ¸ðµÎ CN 802 ºÐ¼®±âÀÇ ¶Ù¾î³ ¹Ýº¹¼º°ú Á¤È®¼ºÀ» º¸¿©ÁÖ°í ÀÖ´Ù. ³ôÀº »ý»ê¼º°ú ³í½ºÅé ¼º´ÉÀ» °®Ãá CN 802 ¿¬¼Ò ÀåÄ¡´Â
³ôÀº 󸮷®¿¡ ÀÌ»óÀûÀÌ¸ç ¿ÏÀü ÀÚµ¿ÈµÇ¾î ÀÖ°í ºÐ¼®´ç 2-5ºÐÀÌ ¼Ò¿äµÇ¾î ºü¸¥ ½ÇÇèÀ» º¸ÀåÇÑ´Ù.
Main advantages of VELP Combustion analyzer
¡Ü |
½Ã·á´ç 3-4ºÐÀÇ ¸Å¿ì ½Å¼ÓÇÑ ºÐ¼®½Ã°£ |
¡Ü |
Áú¼Ò 0.001mg ±îÁö ÃøÁ¤ÇÒ ¼ö ÀÖ´Â ÃÊÁ¤¹Ð ÃøÁ¤´É·Â°ú 0.5% (EDTA) º¸´Ù ÈξÀ ³·Àº »ó´ëÇ¥ÁØÆíÂ÷¸¦ º¸À̴ Ź¿ùÇÑ ÀçÇö¼º |
¡Ü |
Çõ½ÅÀû ±â¼ú°ú Á¤Ç°¼Ò¸ðÇ° Áö¿ø¿¡ ÀÇÇÑ ¸Å¿ì ³·Àº ½Ã·á´ç ÃøÁ¤ ºñ¿ë |
¡Ü |
¸Å¿ì ½±°í ºü¸¥ Àåºñ ¼³Ä¡ |
¡Ü |
´©±¸³ª ¼Õ½±°Ô ÇÒ ¼ö ÀÖ´Â Àåºñ À¯Áö º¸¼ö |
¡Ü |
´©±¸³ª ½±°Ô »ç¿ëÇÒ ¼ö ÀÖµµ·Ï ¼³°èµÈ User Interface |
CN 802 Carbon and Nitrogen Elemental Analysis
|
|
|
|