Cat. No.
UCI Hardness Detector T-U3 °ßÀû¿äû

º»Ã¼¿¡¼­ 78kHz ÀÇ ÃÊÀ½Æĸ¦ UCI probe ¿¡ °¡ÇØÁÖ¸é UCI probe ´Â ÇØ´ç ÃÊÀ½ÆÄÀÇ Ãæ°Ý·ÂÀ» ÃøÁ¤ÇÏ°íÀÚ ÇÏ´Â ±Ý¼Ó¿¡ °¡ÇØÁÖ°Ô µÇ°í ±Ý¼Ó¸é¿¡¼­ Ãæ°ÝÀ» ¹ÞÀº UCI probe ´Â ¹Ýµ¿À» ÇÒ ¶§ ±Ý¼ÓÀÇ hardness ¿¡ µû¶ó ÃÊÀ½ÆÄ ÁÖÆļö¿¡ º¯È­°¡ ÀϾ°Ô µÈ´Ù.
UCI hardness tester ´Â ÀÌ ÃÊÀ½ÆÄ ÁÖÆļö º¯È­¸¦ ÃøÁ¤ÇÏ¿© ±Ý¼ÓÀÇ hardness ¸¦ ÃøÁ¤ÇÏ´Â ÀåÄ¡ÀÌ´Ù.

ASTM A1038 Ç¥Áر԰ݿ¡ ÀûÇÕ
ÁÖ·Î ±Ý¼ÓÀÇ hardness ¸¦ ÃøÁ¤Çϴµ¥ »ç¿ë
ÃÖÀú 1mm µÎ²²±îÁö ¾ãÀº ±Ý¼Ó¹°ÁúÀÇ harness ÃøÁ¤ °¡´É
ÃÖÀú 100g ¹«°Ô±îÁö ¸Å¿ì ÀÛÀº ±Ý¼Ó±îÁö hardness ÃøÁ¤°¡´É
UCI probe ³¡¿¡´Â ±Ý¼Ó¸é¿¡ Ãæ°ÝÀ» °¡ÇÏ´Â µ¥ ÃæºÐÇÑ °æµµ¸¦ °¡Áø ´ÙÀ̾Ƹóµå ÀçÁúÀÇ indenter ÀåÂø
°¢±â ´Ù¸¥ load ¸¦ °¡Áø UCI probe ¼±Åà °¡´É
(10N, 50L ±×¸®°í 90N)
: ÃøÁ¤ÇÏ°íÀÚ ÇÏ´Â ±Ý¼Ó¹°ÁúÀÇ Æ¯¼º¿¡ µû¶ó °¢±â ´Ù¸¥ load ¸¦ °¡Áø UCI probe »ç¿ë, 50N UCI probe °¡ °¡Àå ³Î¸® »ç¿ë
¼ÒÇü Ä«¸Þ¶ó°¡ ³»ÀåµÇ¾î ÀÖ¾î UCI probe ÀÇ Ãþ°Ý¿¡ ÀÇÇØ »ý¼ºµÈ »ùÇà ±Ý¼Ó¸éÀÇ ¸Å¿ì ÀÛÀº Ãæ°ÝÀÚ±¹À» ÃÔ¿µ °¡´É
ÃøÁ¤µÈ hardness ¸¦ ´Ù¾çÇÑ ´ÜÀ§ÀÇ hardness ·Î Ç¥Çö °¡´É
ÃøÁ¤ °æµµ scale ¹üÀ§
: HV (Vickers Hardness Tester) : 230 ~ 940
  HRC (Rockwell Hardness Test) : 20 ~ 70
  HB (Brinell Hardness Tester) : 90 ~ 650
  Tensile strength (Mpa) : 370 ~ 1740
°æµµ ÃøÁ¤ Á¤¹Ðµµ : ¡¾3%HV, ¡¾1.5%HRC, ¡¾3%HB
calibration °ú »ç¿ë »ùÇà ÀÚ·á 88°³ ÀúÀå °¡´É
probe ¿¡ ÃøÁ¤ °á°ú ÀúÀå ±â´É





Specifications of UCI Hardness Tester T-U3
UCI probe types 1kgf (10N), 5kgf (50N), 10kgf (98N)
Measuring Range HV : 230~940,   HRC : 20~70,   HB:90~650,
Measuring accuracy HV:¡¾3%HV;   HRC:¡¾1.5%HRC;   HB:¡¾3%HB
Indenter UCI probe : Diamond indenter
Standards ASTM A1038
Measuring Direction Any direction 360¡Æ
Data Storage Limited only by the memory card up to 32Gb
Communication Upload data to PC and export as a spreadsheet (USB cable and software included )
Hardness Scale UCI probe : HRC, HB, HV
Materials - UCI probe : pre-calibrated for steel.
- Additional custom materials for calibration.
Data display Load applied/contact (UCI),   Single test result,   Max. Min. Average of tests,   Number of tests,
Deviation,   Var. coeff. Histogram,   Signal and Smart Mode (Filter of incorrect measurements).
Indication Color LCD display (320x240)
Operating Environment Temperature : -20¡ÆC ~ 40¡ÆC
Humidity : 30% ~ 80% R.H.
Power Supply DC 4.5V (3 pc batteries AA)
Dimensions 160 x 75 x 30mm
Net Weight Approx. 0.3kg (Without probe)
Battery life Approx. 10 hours.



 